Terle - telco echo return loss enhancement, Uid - unit id, Ver - version – ClearOne XAP TH2 User Manual
Page 49: Appendices ~ appendix c: serial commands, Argument details

45
Appendices
~ Appendix C: Serial Commands
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
TERLE - Telco Echo Return Loss Enhancement
This command reports the Telco echo return loss enhancement.
This command is read only.
Command form: DEVICE TERLE
Argument details
Name
Description
Units
Channel
See Groups and Channels, page 29
Group
17 (R)
Value
(Sent with a Null in text)
dB
Example:
#74 TERLE 1 -24
On XAP 400 unit 4 (#74), the telco echo return
loss enhancement (TERLE) for the hybrid (1) is -24dB.
UID - Unit ID
This command reports the unit ID. This command is read only.
Command form: DEVICE UID [Value]
Argument details
Name
Description
Units
Device
0–F or * to select all units
UID
Command
Value
Null to return value
Hexadecimal
Example:
#63 UID B465F991
The unit ID number (UID) received from XAP TH2
unit 3 (#63), is B456F991.
VER - Version
This command reports the firmware version of the unit. This command is read only.
Command form: DEVICE VER [Value]
Argument details
Name
Description
Device
0–F or * to select all units
VER
Command
Value
Null to return value
Example:
#64 VER 1.0.0 The version of the firmware (VER) programmed
into XAP TH2 unit 4 (#64), is 1.0.0.