beautypg.com

Terle - telco echo return loss enhancement, Uid - unit id, Ver - version – ClearOne XAP TH2 User Manual

Page 49: Appendices ~ appendix c: serial commands, Argument details

background image

45

Appendices

~ Appendix C: Serial Commands

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

TERLE - Telco Echo Return Loss Enhancement

This command reports the Telco echo return loss enhancement.

This command is read only.

Command form: DEVICE TERLE [Value]

Argument details

Name

Description

Units

Channel

See Groups and Channels, page 29

Group

17 (R)

Value

(Sent with a Null in text)

dB

Example:

#74 TERLE 1 -24

On XAP 400 unit 4 (#74), the telco echo return

loss enhancement (TERLE) for the hybrid (1) is -24dB.

UID - Unit ID

This command reports the unit ID. This command is read only.

Command form: DEVICE UID [Value]

Argument details

Name

Description

Units

Device

0–F or * to select all units

UID

Command

Value

Null to return value

Hexadecimal

Example:

#63 UID B465F991

The unit ID number (UID) received from XAP TH2

unit 3 (#63), is B456F991.

VER - Version

This command reports the firmware version of the unit. This command is read only.

Command form: DEVICE VER [Value]

Argument details

Name

Description

Device

0–F or * to select all units

VER

Command

Value

Null to return value

Example:

#64 VER 1.0.0 The version of the firmware (VER) programmed

into XAP TH2 unit 4 (#64), is 1.0.0.