beautypg.com

Ad - auto-disconnect enable/disable, Alc - automatic level control, Baud - baud rate – ClearOne XAP TH2 User Manual

Page 37: Appendices ~ appendix c: serial commands, Argument details

background image

33

Appendices

~ Appendix C: Serial Commands

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

AD - Auto-Disconnect Enable/Disable

This command selects/reports the setting of auto-disconnect.

Command form: DEVICE AD [Value]

Argument details

Name

Description

Channel

See Groups and Channels on page 29

Value

0 = Off, 1 = Loop Drop, 2 = Call Progress

3 = Loop Drop + Call Progress

(Null to query in text)

Example: #62 AD 1 3

On XAP TH2 unit 2 (#62), auto-disconnect (AD) on channel

1 (1) is set to Loop Drop + Call Progress (3).

ALC - Automatic Level Control

This command selects/reports the state of the automatic level control.

Command form: DEVICE ALC [Value]

Argument details

Name

Description

Channel

See Groups and Channels, page 29

Group

17 (R)

Value

0 = Off, 1 = On, 2 = Toggle

(Null to query in text)

Example #62 ALC 1 1

On XAP TH2 unit 2 (#62), the automatic level control

(ALC) for the hybrid (1) is on (1).

BAUD - Baud Rate

This command selects/reports the baud rate of the serial port.

Command form: DEVICE BAUD [Value]

Argument details

Name

Description

Value

9600, 19200, 38400, 57600

(Null to query in text)

Example: #66 BAUD 38400

On XAP TH2 unit 6 (#76), the baud rate (BAUD)

for the RS-232 port is set to 38,400 (38400).