Ad - auto-disconnect enable/disable, Alc - automatic level control, Baud - baud rate – ClearOne XAP TH2 User Manual
Page 37: Appendices ~ appendix c: serial commands, Argument details

33
Appendices
~ Appendix C: Serial Commands
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
AD - Auto-Disconnect Enable/Disable
This command selects/reports the setting of auto-disconnect.
Command form: DEVICE AD
Argument details
Name
Description
Channel
See Groups and Channels on page 29
Value
0 = Off, 1 = Loop Drop, 2 = Call Progress
3 = Loop Drop + Call Progress
(Null to query in text)
Example: #62 AD 1 3
On XAP TH2 unit 2 (#62), auto-disconnect (AD) on channel
1 (1) is set to Loop Drop + Call Progress (3).
ALC - Automatic Level Control
This command selects/reports the state of the automatic level control.
Command form: DEVICE ALC
Argument details
Name
Description
Channel
See Groups and Channels, page 29
Group
17 (R)
Value
0 = Off, 1 = On, 2 = Toggle
(Null to query in text)
Example #62 ALC 1 1
On XAP TH2 unit 2 (#62), the automatic level control
(ALC) for the hybrid (1) is on (1).
BAUD - Baud Rate
This command selects/reports the baud rate of the serial port.
Command form: DEVICE BAUD [Value]
Argument details
Name
Description
Value
9600, 19200, 38400, 57600
(Null to query in text)
Example: #66 BAUD 38400
On XAP TH2 unit 6 (#76), the baud rate (BAUD)
for the RS-232 port is set to 38,400 (38400).