AA - Auto-Answer Enable/ Disable

This command selects/reports the setting of auto-answer.

Command form: DEVICE AA [Value]

Argument details

Name

Description

Channel

See Groups and Channels on page 29

Value

0 = Off, 1 = On, 2 = Toggle

Example: #61 AA 1 1

On XAP TH2 unit 1 (#61), auto-answer (AA) for telco

channel (1) is set on (1).

ACONN - Audible Connect / Disconnect

Indication

This command selects/reports the status of the audible connect/disconnect indication.

Command form: DEVICE ACONN [Value]

Argument details

Name

Description

Channel

See Groups and Channels on page 29

Value

0 = Off, 1 = On, 2 = Toggle, (Null to query in text)

Example: #60 ACONN 1 1

On XAP TH2 unit 0 (#60), audible connect/disconnect

(ACONN) for telco channel 1 (1) is set on (1).

ACONNLVL - Audible Connect/Disconnect Level

This command selects/reports the audible connect/disconnect indicator’s level.

Command form: DEVICE ACONNLVL [Value]

Argument details

Name

Description

Units

Channel

See Groups and Channels on page 29

Value

-12.00–12.00

dB

(Null to query in text)

Example: #64 ACONNLVL 1 -6

On XAP TH2 unit 4 (#64), audible

connect/disconnect level (ACCONLVL) on channel 1 (1) is set to -6dB (-6).