beautypg.com

Using meters, Telco meters – ClearOne XAP TH2 User Manual

Page 27

background image

23

Optimization

~ Telco Meters

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Using meters

Open the XAP TH2 Telco Meters window by clicking the Telco Meters button on the

XAP TH2 Flow Screen. The Telco Meters window is a diagnostic tool which allows

you to observe the performance of various aspects of XAP TH2 operation. Refer to

the Transmit and Receive meters when making level adjustments.

Telco Echo Return Loss (TERL)

The Telco Echo Return Loss meter shows the coupling between the transmit signal

and the input to the telephone echo canceller. It is the ratio of the two levels. The

range of the meter is -30 to +20dB. It is a peak meter and updates only when

transmit signal is present.

Telco Echo Return Loss Enhancement (TERLE)

The Telco Echo Return Loss Enhancement meter shows the loss through the

telephone echo cancellation and non-linear processing chain. It is the ratio of the two

Figure 5.1. XAP TH2 Telco Meters window

Telco Meters