RXRD - Telco Receive Reduction

This command selects/reports the status of the Telco receive reduction.

Command form: DEVICE RXRD [Value]

Argument details

Name

Description

Channel

See Groups and Channels, page 29

Group

17 (R)

Value

0 = Off, 1 = On, 2 = Toggle, (Null to query in text)

Example: #65 RXRD 1 0

On XAP TH2 unit 5 (#65), the receive reduction

(RXRD) for the hybrid (1) is off (0).

SERECHO - Serial Echo

This command selects/reports the serial echo of the RS-232 port.

Command form: DEVICE SERECHO [Value]

Argument details

Name

Description

Value

0 = Off, 1 = On, 2 = Toggle

(Null to query in text)

Example: #64 SERECHO 1

On XAP TH2 unit 4 (#64), the serial echo

(SERECHO) of the RS-232 port is set to on (1).

SERMODE - Serial Mode

This command selects/reports the serial mode of the RS-232 port.

Command form: DEVICE SERMODE [Value]

Argument details

Name

Description

Value

1 = Text, 2 = Binary, (Null to query in text)

Example: #65 SERMODE 1

On XAP TH2 unit 5 (#65), the RS-232 port serial

mode (SERMODE) is set to text (1).