Configuration ~ g-ware – ClearOne XAP TH2 User Manual

Page 16

background image

Configuration

~ G-Ware

12

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

2.

If you have already established a connection with the site, the Device

ID

will be assigned. If you are working offline, select the Device ID that

matches the ID you assigned the unit via the back-panel DIP switches.

Device IDs ensure the software will sync up with the proper unit when there

are multiple TH2s on a network.

3.

Adjust the Meter Refresh rate as necessary. The default rate is 50ms.

4.

Select the country where this product is being used from the

Country Code

list.

Warning: The country code must be set correctly to ensure that the unit

operates properly when connected to the telco network and complies with

the country’s telco requirements. Changing this code to a country other

than the intended country of operation might cause the XAP TH2 to be

non-compliant.

5.

Click the Comm tab. The Baud Rate and Flow Control settings are changed

using the Site Properties window. Select the Serial Echo and Serial Mode

you want to use.

Serial Echo enables the unit to echo back the commands you send over the

E-bus network. Serial Mode determines the format (binary or text) in which

the commands return over the E-bus network. The default setting when

G-Ware is connected to a unit is binary. When the unit is disconnected, the

default is text.

6.

Select Use Modem if a modem will be used with the unit.

7.

Click the Security tab to enter a Modem Password. This password will be

required for all connections made to the RS-232 port whether it be modem,

direct connection to PC, or AMX touch panel.

8.

Click OK to save settings and close the Unit Properties window.

You will need to repeat this process for all XAP TH2 units on your network.

Figure 3.2. Unit Properties General tab

Figure 3.3. Unit Properties Comm tab

Figure 3.4. Unit Properties Security tab