ELR 7000 Series Multi Point Lock
SIgNal
CauSE
TROuBlEShOOTINg
Dark / Unlit
Controller microprocessor is not active
Confirm connections and incoming power
Steady Flashing (GREEN)
Normal operation
Cycle device by closing the timer circuit
Solid Light (GREEN)
Input voltage is dropping out of operating range
Check wire run and power supply output
1 Flashes Followed by Pause (YELLOW)
Retractor sensor problem
Call 800-810-WIRE for assistance
2 Flashes Followed by Pause (YELLOW)
Retractor sensor problem
Call 800-810-WIRE for assistance
3 Flashes Followed by Pause (YELLOW)
Retractor sensor problem
Call 800-810-WIRE for assistance
5. LED Signalling Chart
4.
TIMER MODE Adjustment (Onboard Timer)
How it works: The 24/12 volt input is always energized and the system retracts when the timer input circuit
is closed.
• When the timer circuit is closed utilizing a
momentary switch, the device retracts, remains retracted for a set
duration, and releases. The duration of the retraction is set using an onboard timer setting (0 - 20 second timer
adjustment). The countdown begins when the rail is first retracted.
• When the timer circuit is closed using a
maintain switch, the device retracts.
The device releases when the circuit is re-opened.
Notes:
• Note: 24V/12V supply is constant in
TIMER MODE. The duration of retraction is determined by whichever is
longer: the maintain switch closure or the onboard timer delay.
• If more than 20 seconds delay is necessary (exceeding the maximum setting), an external timer delay relay
is required (not provided).
Note: Refer to Figure. 3 for DIP Switch timer delay settings.
Fig. 3 Timer Delay Settings
(Default = 0 Seconds)
0 Seconds
2 Seconds
3 Seconds
4 Seconds
5 Seconds
10 Seconds
15 Seconds
20 Seconds
1 2 3 4
DELAY
Fig. 3 Settings Location
DIP switch
setting location