ULTRA-CUT 100 XT

Manual 0-5303

OPERATION

�-23

CCM Status Code

Group 4 -- Torch Coolant System

Code

Message

Remedy / Comments

401

Coolant Level low

Check coolant level, add as needed. Defective or disconnected level sensor.

402

Low coolant flow

Coolant flow as measured by flow switch FS1 is less than 0.7 gpm; Clogged filter;

Restriction in torch lead or head; Wrong style consumables; broken or defective

torch coolant tube/check valve; Defective pump or bypass valve.

403

Coolant overheated

Coolant supply temperature exceeded 75 degrees Celcius (167F). Operating with

side panel loose or removed; Air flow blocked at air inlet or exit of power supply;

Coolant fan failed; radiator fins clogged with dirt.

404

Coolant System not

ready.

Proper coolant flow of 0.7 gpm as measured by flow switch FS1 was not obtained

during up to 4 minutes of Priming. New installation can require additional Priming

cycle(s) to fill hoses with coolant; cylce power to restart Priming; Coolant hoses

or torch hoses reversed; Clogged coolant filter; Restriction in torch lead or head;

Wrong style consumables; broken or defective torch coolant tube/check valve;

Defective or disconnected FS1 flow SW; Defective pump or bypass valve.

405

Low Coolant Level Warn-

ing

Low coolant level during cut, does not stop cut.

Add coolant as required.

406

Coolant Flow Low Warn-

ing.

This is a warning, does not stop system operation. Coolant flow rate lower than ex-

pected. Can be caused by gas bubbles being introduced into the coolant or wrong or

mismatched or worn consumable parts; Failed seals in torch cartridge or torch body;

Clogged coolant filter; Restriction in torch lead or head; defective or disconnected

FL1 flow sensor.

407

Coolant overheated, high

ambient.

Coolant supply temperature exceeded 75 degrees Celsius (167 Fahrenheit) likely

cause ambient greater than 40 degrees Celsius (104 Fahrenheit); Reduce cutting

duty cycle; Reduce ambient temperature; Add separate coolant cooler.

CCM Status Code

CCM-Group-5 Gas Controller Communication Port

Code

Message

Remedy / Comments

501

CANBUS Acknowledge

Fault

CCM to DMC Fiber-optic Control cable not connected, not

properly connected or cable defective. DMC power supply

or Control PCB defective. Defective CCM, replace.

502

CANBUS Off

Dirt on fiber ends or in connectors; blow out with clean dry

air; Fiber not locked into connector; Sharp bends in fiber;

Fiber defective

503

CANBUS Errors Warning

Dirt on fiber ends or in connectors; blow out with clean dry

air; Fiber not locked into connector; Sharp bends in fiber;

Fiber defective;

50�

Reserved

No information available; Contact customer service