Ultra-cut 100 xt – Tweco 100 Ultra-Cut Plasma Cutting System with Automated Gas Control User Manual
Page 86
ULTRA-CUT 100 XT
�-1�
OPERATION
Manual 0-5303
B. Shield Gases
1. Compressed Air Shield
• Air shield is normally used when operating with air or oxygen plasma.
• Improves cut quality on some ferrous materials.
• Inexpensive - reduces operating costs.
2. Nitrogen (N2) Shield
• Nitrogen shield is used with nitrogen (N2) or Ar/H2 (H35) plasma.
• Provides smooth finishes on nonferrous materials.
• May reduce smoke when used with Ar/H2 plasma.
3. Water Shield
• Normally used with nitrogen.
• Provides very smooth cut surface.
• Reduces smoke and heat input to the workpiece.
• Effective when used with N2 up to 2 inch (50mm) maximum material thickness.
• Tap water provides low operating expense.
Operational Suggestions
1. Wait four minutes before setting the ON/OFF switch to OFF after operation. This allows the cooling fans to
run to dissipate operating heat from the power supply.
2. For maximum parts life, do not operate the pilot arc any longer than necessary.
3. Use care in handling torch leads and protect them from damage.
�. When using water as the shield note the following:
• Use clean drinking quality tap water to help prevent particulate build-up within the system water shield
plumbing.
• Particulate contamination and bulid-up can cause reduced consumable parts life and premature torch
failure.
• A cartridge type particulate water fi lter may help achieve optimum cutting performance.