beautypg.com

05 precision plasma cutting torch, 06 specifications & electrical requirements, Precision plasma cutting torch -2 – Tweco 100 Ultra-Cut Plasma Cutting System with Automated Gas Control User Manual

Page 18: Specifications & electrical requirements -2, Ultra-cut 100 xt

background image

ULTRA-CUT 100 XT

2-2

SPECIFICATIONS

Manual 0-5303

2.05 Precision Plasma Cutting Torch

The torch delivers the controlled current to the work through the main arc, causing the metal to be cut.

2.06 Specifications & Electrical Requirements

100 Amp System

Ultra-Cut 100 XT™ Specifications & Design Features

Max OCV (U0)

425 vdc

Minimum Output Current

5 Amps

Max Output Current

100 Amps

Output Voltage

60 - 180 vdc

Duty Cycle Rating

100% @ 100A, 200V, (20kW),

Ambient Temperature

for Duty Cycle Rating

104F° (40°C)

Operating range

14°F to 122°F (-10°C to + 50°C)

Power Factor

0.94 @ 100 A DC Output

Cooling

Coolant and Forced Air (Class F)

Ultra-Cut 100 XT™ Power Supply

Input

Power Input

Current

Suggested Sizes (See Note)

Voltage

Freq.

3-Ph

3-Ph

Fuse (Amps) Wire (AWG)

Wire (mm

2

)

(Volts)

(Hz)

(kVA)

(Amps)

3-Ph

3-Ph

3-Ph

480

50/60

21

26

35-40

#12

4

NOTE

* Suggested wire size based on United States NFPA 70 National Electrical Code 2011 edition published by the
National Fire Prevention Association. Listings are from table 400.5(A)(2) for flexible cord of certain types rated
for 75 deg C in ambient temperatures up to �0 deg C. Using wires of lower temperature rating or different insu�

deg C in ambient temperatures up to �0 deg C. Using wires of lower temperature rating or different insu�

C in ambient temperatures up to �0 deg C. Using wires of lower temperature rating or different insu�

lation type may require larger wire size. De rate for higher ambient.
These are suggestions only. Always refer to your local and national codes that apply to your region for final
determination of correct wire type and size.