INSTALLATION

Manual 0-5303

3.07 Connect Work Cable and Pilot and Negative Leads

1. Remove the output power cover to the left of the coolant filter at the rear of the power supply. To do this

remove the two screws then lift up and pull away.

2. Route the ends of the work cable, pilot and negative/torch leads upward through the leads strain relief at the

bottom edge of the left rear panel.

3. Refer to the illustration. Connect the leads as shown. Tighten securely. Do not overtighten.

Art # A-11533

Pilot

Work Cable

Torch

+ -

4. Reinstall the cover on the power supply. Snug the hardware securely by hand. Do not overtighten.

3.08 Ground Connections

0 - 10 ft (0 - 3 m) Ideal

20 ft (6 m) Maximum

1/0

Ground Cable

Power Supply

‘Star’

Ground

Earth Ground

Rod

See

Manufacturer

CNC

Device

Torch

Cutting Table

Cutting Machine / Gantry

3/0 Work Cable

Remote Arc

Starter (RAS-1000)

Star Ground on Cutting Table

Note: The gas control module can
be mounted on top of the power
supply.
If it is, it should be grounded
directly to the power supply with
#4 AWG ground, (F).
Any location requires grounding
the power supply to the
‘Star’ ground with the 1/0
Ground Cable (F1).

Gas Control Module

Primary location

#4 AWG

Ground

(F)

Customer supplied

1/0

Ground Cable

(F1)

Art # A-11875

1/0 Ground Cable