Led lightbar, Esf1 øøø skyfire™ led lightbar – SoundOff Signal SkyFire LED User Manual
Page 3
![background image](/manuals/594222/3/background.png)
Skyfire™ LED Lightbar Owner's Manual ESF1ØØØ.pdf ~ Rev. 01.12
Pg. 3
FLASH PATTERNS
Left against Right
1. Warp
6. ALTERNATING WARP 1, 2, 3
2. Quad
7. Alternating Progressive
3. Quad2
8. Q-Switch™
4. Quint
9. Intercycle
5. Double2
Whole Bar
10. Warp
14. Double2
11. Quad
15. Warp 1, 2, 3
12. Quad2
16. Solid Progressive
13. Quint
Criss-Cross Patterns
17. Warp
22. ALTERNATING WARP
18. Quad
23. Alternating Progressive
19. Quad2
24. Q-Switch™
20. Quint
25. Intercycle
21. Double2
Chase Patterns
26. Opposite Sides 1x1
Cycle Patterns
27. Solid On, three flashes
To Program Warning Lights/Select Flash Patterns:
All Warning lights are activated using the 12 conductor cable that exits the bar. All wire colors referenced in the below instructions refer to the 12 conductor cable.
For Complete Bar Simultaneous or Alternating Synchronized Patterns:
1. Activate all WARNING modules by applying +10-16 Vdc to the RED, ORANGE, BLUE, GREEN and BLUE/BLACK wires. Apply BLACK wire to Ground.
2. Momentarily touching and removing the WHITE wire to ground for no more than one second will advance the lightbar to the next flash pattern. See flash
pattern table provided below for complete list. Continuing to touch and remove the WHITE wire to ground will allow you to scroll through the pattern list. After
the last pattern, #28 is reached the patterns will start over beginning at flash pattern #1.
3. To go back one flash pattern: Touch WHITE wire to ground for more than two seconds but less than five seconds.
4. To reset to flash pattern #1: Touch WHITE wire to ground for more than five seconds. Lightbar will reset to flash pattern #1 after five seconds.
For Individual Corner and Inboard Simultaneous and Alternating Synchronized Patterns:
1. Apply +10-16 Vdc to activate the desired WARNING modules using the activation wires outlined in the diagram provided.
2. Momentarily touching and removing the WHITE wire to ground for no more than one second will advance the modules to the next flash pattern. See flash
pattern table provided below for complete list.
3. To go back one flash pattern: Touch WHITE wire to ground for more than two seconds but less than five seconds.
4. To reset to flash pattern #1: Touch WHITE wire to ground for more than five seconds. Lightbar will reset to flash pattern #1 after five seconds.
NOTE: SKYFIRE™ is equipped with Flash Pattern Recall. Once you have selected a pattern the lightbar will always activate to that pattern every time the unit is
powered up. Remember to tape up and secure WHITE wire so that it will not accidentally change your selected pattern once set.
#ESF1
ØØØ Skyfire™ LED Lightbar
LED Lightbar
tm
RED
ORANGE
BLUE
GREEN
BLUE/BLACK
GROUND
BLACK
GREEN/BLACK
RED/BLACK
ORANGE/BLACK
WHITE
WHITE/BLACK
GROUND
GREEN
BLACK
RED
GROUND
WORK LIGHT
S
(IF INST
ALLED
)
CABL
E
MAIN INPUT CABL
E
LIGHT
BAR
+10-16 Vdc
+10-16 Vdc
Vehicle Tail Output +10-16 Vdc
Vehicle Left Turn Output +10-16 Vdc
Vehicle Right Turn Output +10-16 Vdc
Vehicle Stop Output +10-16 Vdc
Rear Inboard
Rear Corner
Front Inboard
Front Corner
+10-16 Vdc
10 Amp Fuse
(customer supplied)