beautypg.com

Led lightbar, Esf1 øøø skyfire™ led lightbar – SoundOff Signal SkyFire LED User Manual

Page 3

background image

Skyfire™ LED Lightbar Owner's Manual ESF1ØØØ.pdf ~ Rev. 01.12

Pg. 3

FLASH PATTERNS

Left against Right

1. Warp

6. ALTERNATING WARP 1, 2, 3

2. Quad

7. Alternating Progressive

3. Quad2

8. Q-Switch™

4. Quint

9. Intercycle

5. Double2

Whole Bar

10. Warp

14. Double2

11. Quad

15. Warp 1, 2, 3

12. Quad2

16. Solid Progressive

13. Quint

Criss-Cross Patterns

17. Warp

22. ALTERNATING WARP

18. Quad

23. Alternating Progressive

19. Quad2

24. Q-Switch™

20. Quint

25. Intercycle

21. Double2

Chase Patterns

26. Opposite Sides 1x1

Cycle Patterns

27. Solid On, three flashes

To Program Warning Lights/Select Flash Patterns:

All Warning lights are activated using the 12 conductor cable that exits the bar. All wire colors referenced in the below instructions refer to the 12 conductor cable.

For Complete Bar Simultaneous or Alternating Synchronized Patterns:
1. Activate all WARNING modules by applying +10-16 Vdc to the RED, ORANGE, BLUE, GREEN and BLUE/BLACK wires. Apply BLACK wire to Ground.
2. Momentarily touching and removing the WHITE wire to ground for no more than one second will advance the lightbar to the next flash pattern. See flash
pattern table provided below for complete list. Continuing to touch and remove the WHITE wire to ground will allow you to scroll through the pattern list. After
the last pattern, #28 is reached the patterns will start over beginning at flash pattern #1.
3. To go back one flash pattern: Touch WHITE wire to ground for more than two seconds but less than five seconds.
4. To reset to flash pattern #1: Touch WHITE wire to ground for more than five seconds. Lightbar will reset to flash pattern #1 after five seconds.

For Individual Corner and Inboard Simultaneous and Alternating Synchronized Patterns:
1. Apply +10-16 Vdc to activate the desired WARNING modules using the activation wires outlined in the diagram provided.
2. Momentarily touching and removing the WHITE wire to ground for no more than one second will advance the modules to the next flash pattern. See flash
pattern table provided below for complete list.
3. To go back one flash pattern: Touch WHITE wire to ground for more than two seconds but less than five seconds.
4. To reset to flash pattern #1: Touch WHITE wire to ground for more than five seconds. Lightbar will reset to flash pattern #1 after five seconds.
NOTE: SKYFIRE™ is equipped with Flash Pattern Recall. Once you have selected a pattern the lightbar will always activate to that pattern every time the unit is

powered up. Remember to tape up and secure WHITE wire so that it will not accidentally change your selected pattern once set.

#ESF1

ØØØ Skyfire™ LED Lightbar

LED Lightbar

tm

RED

ORANGE

BLUE

GREEN

BLUE/BLACK

GROUND

BLACK

GREEN/BLACK

RED/BLACK

ORANGE/BLACK

WHITE

WHITE/BLACK

GROUND

GREEN

BLACK

RED

GROUND

WORK LIGHT

S

(IF INST

ALLED

)

CABL

E

MAIN INPUT CABL

E

LIGHT

BAR

+10-16 Vdc

+10-16 Vdc

Vehicle Tail Output +10-16 Vdc

Vehicle Left Turn Output +10-16 Vdc

Vehicle Right Turn Output +10-16 Vdc

Vehicle Stop Output +10-16 Vdc

Rear Inboard

Rear Corner

Front Inboard

Front Corner

+10-16 Vdc

10 Amp Fuse

(customer supplied)