background image

ATC200-LITE-USB Teletilt

®

RET System

Section 13–Device Configuration with SmartBeam™ Antennas

Bulletin 639536 • Revision L

October

2014

13-3

4. SmartBeam antennas do not change the assigned Antenna Model.

For the most current listing of antenna models designed for use with the ATC200-LITE-USB
Teletilt system, see the Products tab on the CommScope website.

5. Use

the

Antenna Type drop down list to select the antenna type that is correct for the antenna

model selected (Figure 13-2). Note that this value is used for reference only and has no direct
affect upon the Actuator/Antenna that is being configured.

6. The serial number of SmartBeam antennas is pre-set and cannot be changed.(Figure 13-2).

7. Using the drop down lists and entry fields, specify the parameters for the remaining fields (Op-

erating/Frequency Band, Technology, Base Station ID, Installer ID, Install Date, Mechanical Tilt,
Bearing, Height, Sector, and Location). Note the following:

• A positive mechanical tilt angle means that the antenna beam is directed below the

horizontal plane. A negative mechanical tilt angle means that the antenna beam is

directed above the horizontal plane.

• The bearing is the installed compass orientation for this antenna.

• The height of the antenna on the tower must be entered in the range of 1 to 999. No

specific unit of length, such as feet or meters, is associated with this field. However,

you should enter a value that conforms to the units of length customarily used by your

company for antenna installations.

• If in AISG 1.1 mode, the ID for the base station associated with this antenna must be 1 to

12 characters in length, and it may contain any combination of numbers and letters.

When the actuator is in AISG 2.0 protocol mode, the longer station ID consists of 32

characters.

• The Installation Date field is handled differently from all other configuration items. Although

this field is not required, if no installation date has been saved on the actuator the program

will suggest the current date as the default. If the current date is used, it will be saved on

the actuator when the Configure button is activated. Alternately, the suggested date may

be erased and a new date entered, or the field may be left blank. When a date is entered,

it must be formatted as MM/DD/YY as shown in Figure 13-2 (A forward slash character

placed between the month and day and a forward slash character placed between the day

and year) i.e., July 7, 2008 would be typed as 07/07/08.

• The installer’s ID must be 1 to 5 characters in length with any combination of letters
and

numbers.

• Values specified for the frequency band, sector, technology, location, and mechanical tilt are

used for reference only and have no direct affect upon the actuator/antenna that is being

configured.

Frequency band (AISG 1.1)/Operating Band (AISG 2.0) value can have multiple values set.
Click on the drop down arrow in the list to open the multi selection list. Make selection by click-
ing on the check box for the relevant frequency. Click outside the list or press ESC key to close
the list (Figure 13-3).