beautypg.com

CommScope ATC200-LITE-USB User Manual

Page 89

background image

ATC200-LITE-USB Teletilt

®

RET System

Section 12–Adjusting Downtilt-Group of Antennas Multiple Actuators

Bulletin 639536 • Revision L

October

2014

12-3

7. After the devices are moved to the Antennas Included In Move box, examine the group to

ensure that the group does not include any antennas that are not desired for this move.

8. To remove one or more antennas from the group move, either click on that antenna and then

click Remove, or double click on that antenna to move it back to the right hand box.

9. When satisfied with the list of antennas that will be included in the group move, enter a new

downtilt angle and click Activate to start the move (Figure 12-3). Progress for each antenna
movement in the group will be displayed separately.

A progress indicator bar (located to the left of Current Tilt) will continually update for as long as
the move is in progress.

Figure 12-3. Entering New Electrical Tilt Setting for Sector Move.

1.

ngle

may

be entered with the precision of 0.1 degree (Ex: 5.0 or 5.5).

Progress

Display.