TX RX Systems Inc. Manual 7-9120-5 07/26/10 Page 13

5) Fine tune the T-Pass cavity of the expansion

channel according to the fine tuning procedure
outlined earlier.

RELAY RACK PROCEDURE
(6.625” CAVITIES)

Because of their width, 6.625” cavities
are mounted on relay racks in a hori-
zontal or ientation on cavity deck
plates.

1) Determine the location of the expansion chan-

nel in the rack by consulting the new
THRULINE cable chart.

2) If necessary install an empty cavity deck in the

rack using 4 Phillips screws. If there is room on
an already existing cavity deck then skip this
step of the procedure.

3) Mount the cavity on the deck by laying the cav-

ity onto the “V shaped” cavity bracket.

NOTE

Screw

Screw

Screw

Screw

Figure 12: Relay rack mounting details. Ten-inch cavities shown as an example.