AC Line Filters

In addition to EMI/RFI safeguards inherent in the DC3RD
design, external filtering is required. Reliance Electric
requires the Corcom® AC line filters listed in Table 3. Use
model 5VR1 with drives rated for 3 ADC or below, and
model 20VV1 with drives rated for 10 ADC or below.

Table 3. AC Line Filters

Corcom

®

Model Number

5VR1

20VV1

Rated Current

5 A

20 A

Inductance

1.032 mH

0.88 mH

Capacitance

Line to Line

0.303

µ

F

0.303

µ

F

Line to Ground

0.011

µ

F

0.011

µ

F

Discharge Resistor

680 K

680 K

Wire the AC line filter within 0.25 meters of the drive. The
ground connection from the filter must be wired to solid
earth ground (resistance less than 500 ohms); not machine
ground. This is very important!

If the end-user is using a CE-approved motor, the correct
filter from Table 3 is all that is necessary to meet the
EMC directives listed herein.