background image

Drive Rating

Motor HP

Rated AC

Input DC Armature DC Armature

Field

Field

Line Amps kVA

Voltage

Current

Voltage

Current

1/4

4.2

0.48

90

2.7

50

1

4.2

0.97

180

2.7

100

1

1/3

5.5

0.63

90

3.5

50

1

5.5

1.27

180

3.5

100

1

1/2

7.5

0.86

90

5

50

1

3.8

0.87

180

2.5

100

1

3.8

0.87

180

2.5

200

1

3/4

10.9

1.25

90

7.6

50

1

5.9

1.36

180

3.8

100

1

5.1

1.17

180

3.8

200

1

1

12.1

1.39

90

10

50

1

6.7

1.54

180

5

100

1

6.7

1.54

180

5

200

1

1 1/2

--

--

--

--

--

--

9.8

1.25

180

7

100

1

9.8

2.25

180

7

200

1

2

--

--

--

--

--

--

11.7

2.69

180

9.2

100

1

11.7

2.69

180

9.2

200

1

3

Specifications

250-0285-rev1.qxd 4/26/00 9:36 AM Page 3