25

Operation

1. Press the forward pushbutton for

forward motor rotation.

2. Motor rotates in the forward

direction until the forward limit
switch opens.

3. The motor stops and dwells when the

forward limit switch opens. Set the
dwell time by calibrating the DWELL
TIME trimpot (see page 23).

4. Motor rotates in the reverse

direction until the reverse limit
switch opens.

5. The motor stops when the reverse

limit switch opens. Return to step 1
to repeat the process.

Press FWD to go forward.

Reverse

Limit

Switch

Forward

Limit

Switch

Forward Direction

Reverse Direction

STOP

AND

DWELL

STOP

Mode 2 – Single cycle between forward and reverse
limit switches

• Single cycle automatically returns travel to the reverse

limit switch location.