Operation

Mode 3 – Continuous cycle between forward and
reverse limit switches

1. Press the forward pushbutton for

forward motor rotation.

2. Motor rotates in the forward

direction until the forward limit
switch opens.

3. The motor stops and dwells when

the forward limit switch opens. Set
the dwell time by calibrating the
DWELL TIME trimpot (see page
23).

4. Motor rotates in the reverse

direction until the reverse limit
switch opens.

5. The motor stops and dwells when

the reverse limit switch opens.
The process repeats steps 2-5
until you press the STOP
pushbutton.

Reverse

Limit

Switch

Forward

Limit

Switch

Forward Direction

Reverse Direction

STOP

AND

DWELL

STOP

AND

DWELL

Press FWD to go forward.