beautypg.com

Bandpass measurement parameters – Rockwell Automation 1440-VAD02-01RA XM-123 Aeroderivative Module User Manual

Page 64

background image

Publication GMSI10-UM003D-EN-P - May 2010

56

Bandpass Measurement Parameters

There are two instances of the bandpass measurement parameters, one for
each channel. Use these parameters to configure the characteristics of the
bandpass filter.

Bandwidth

Enter the bandwidth for the Constant Bandwidth
filter. The bandwidth is a measure of the width of a
filter.

Hz

Note: This value is used or enabled
only when Constant Bandwidth is
selected as the tracking filter type.

Constant Q

The ratio of the bandwidth to the center frequency
(machine speed) remains the same.

Q

Enter the Q value for the Constant Q filter. Q is the
measure of the sharpness of a filter

Note: This value is used or enabled
only when Constant Q is selected as
the tracking filter type.

Tracking Measurement Parameters

Parameter Name

Description

Values/Comments

IMPORTANT

The bandpass measurement parameters are available for
the channel only when the Bandpass Filter is selected as
the filter measurement. Refer to Aeroderivative
Measurement Parameter on page 55.

Bandpass Measurement Parameters

Parameter Name

Description

Values/Comments

Minimum Frequency

The "highpass corner frequency" or "low cutoff
frequency" of the bandpass filter.

25 to 1000 Hz

Maximum Frequency

The "lowpass corner frequency" or "high cutoff
frequency" of the bandpass filter.

100 to 5500 Hz