Command summary – Rockwell Automation 5370 Color CVIM Communications Manual User Manual
Page 95

Chapter 5
Using the RS–232 Ports
5–27
After you have become familiar with the ASCII commands, you can use the
following command summary as a quick reference guide.
Table 5.A
ASCII Command Summary
Command
Command Structure
Field Descriptions
Deactivate Forces
>DF [CR]
Disable Outputs
>DO [CR]
Enable Outputs
> EO [CR]
Echo Data
>E, data [CR]
Data = ASCII string
Force Outputs
>F, On, d [CR]
n =
1 to 14
d =
0 or 1
Load Configuration From
EEPROM to RAM
>LO [CR]
Load Configuration From RAM
Card to RAM
>LO, CC, d[CR]
d =
1 to 16*
Lock
>L [CR]
Unlock
>U [CR]
Read Output Condition
>R, On [CR]
n =
1 to 14
Read Configurable Statistics
>RSn [CR]
n =
number of times read
Read Configuration
>RC, CBn [CR]
n =
1 to 213
Read All Discrete Bit Results
>RR [CR]
Read Discrete Bit Results
>RR, Pn [CR]
n =
1 or 2
Read Results Block
>RR, RB, d [CR]
>RR,o,d[CR]
>RR,S
**
d = 1, 2, 3, 4, 5, or 6
o =
RL,RW,G,W,LP
d =
gage or window number
S =
Status
Save to EEPROM from RAM
>S [CR]
Save to RAM Card from RAM
>S, CC, d [CR]
d = 1 to 16*
Set Configurable Results
>SR,d,d,etc. [CR]
d =
G1,G2,W1,W2,
RW1, RL3, LP, etc.
*
The number of configurations that can be stored on a RAM card depends upon the card
size (512K card can hold 16 configurations).
**
Refer to Appendix B, Table B.1, RS–232 word 0 for a definition of Color CVIM status.
Command Summary