Panelbuilder device error messages, Panelbuilder translation error messages – Rockwell Automation 2755-SNx Adaptascan Bar Code Readers User Manual
Page 342

17–20
Communicating with PanelView 900
t
Terminals on a DeviceNet Network
Publication 2755-6.8
Message
Recommended Action
Tag:
Reduce the word offset for the associated Tag Address.
Tag:
Certain PanelBuilder controls, however, may require additional bytes. If less
than 2 bytes are required, use Bit Array.
Most PanelBuilder controls write only 1 element of data. If the
associated Data Type is an Unsigned Integer, this implies 2
bytes will be written by the Tag. However, if tags are assigned
to the Block Write of a Piloted Control List, the number of bytes
written will be a multiple of the states displayed on the list.
Tag:
Certain PanelBuilder controls, however, may require additional bytes.
Most PanelBuilder controls write only 1 element of data. If the
associated Data Type is a Floating Point, this implies 4 bytes
will be written by the Tag. However, if tags are assigned to the
Block Write of a Piloted Control List, the number of bytes
written will be a multiple of the states displayed on the list.
Tag:
equal to 2. Certain PanelBuilder controls, however, may require additional
bytes.
Most PanelBuilder controls write only 1 element of data. If the
associated Data Type is an Bit Array, this implies at most 2
bytes will be written by the Tag. However, if tags are assigned
to the Block Write of a Piloted Control List, the number of bytes
written will be a multiple of the states displayed on the list.
Tag:
packet.
If the associated tag is an I/O tag, increase either the Input or
Output Size. If the associated tag is Explicit-Server, the data
size extends beyond the 64 word limit of the Assembly
Instance.
Tag:
packet. Adjust Packet Bytes to at least #.
Increase the Packet Bytes assigned to the tag.
Tag:
tag’s Message Type is inconsistent with previous tags in this group.
Tags have been assigned to a PanelBuilder control that must
be updated in the same data packet. Change the Message
Type so that it is the same as other members of this group.
Tag:
Assembly Instance is inconsistent with the previous tags in this group.
Tags have been assigned to a PanelBuilder control that must
be updated in the same data packet. Change the Assembly
Instance so that it is the same as the other members of this
group.
Tag:
Peer’s Class, Instance, Attribute, or Node Address is inconsistent with previous
tags in this group.
Tags have been assigned to a PanelBuilder control that must
be updated in the same data packet. Change the
Explicit-Client message so that it references the same peer
attribute as other tags assigned to this group.
PanelBuilder Device Error Messages
Message
Recommended Action
Device:
Create a new device entry under the Terminal Setup Dialog.
Device:
parameters will be used.
Update the Communications Setup Dialog to the appropriate
network values. (i.e. Node Address, Baud Rate, etc.)
Device:
Update the Communications Setup Dialog to the appropriate
network values. (i.e. Node Address, Baud Rate, etc.)
PanelBuilder Translation Error Messages
Message
Recommended Action
Too many peer accesses. Only 128 Explicit-Client message channels are
allowed per application.
Reduce the number of Explicit-Client Tags in your application.
Translation Failure
Contact Allen-Bradley for technical support.