42 Blow-molding Module
Publication 1746-IN014B-EN-P - January 2001
Digital Output
Type
Open Collector
Maximum OFF State Voltage
30Vdc
Isolation from PLC backplane
Tested to 500Vdc for 60 sec or equivalent
Output Conductors: Wire size
Belden 8761 or equivalent
22-14 AWG stranded maximum
3/64 inch insulation maximum
Wire Category 2
(2)
Environmental
(1)
Power requirement
5 Watts (1A @ +5Vdc)
Operating (ambient) temperature
0 to 60
°
C
Storage temperature
-40 to +85
°
C
Relative humidity
5 to 95% (non-condensation)
Agency Certifications
When product is marked:
(1)
This product must be mounted within a suitable system enclosure to prevent personal injury resulting from
accessibility to live parts. The interior of this enclosure must be accessible only by the use of a tool. This
industrial control equipment is intended to operate in a Pollution Degree 2 environment, in overvoltage
category II applications, (as defined in IEC publication 664A) at altitudes up to 2000 meters without
derating.
(2)
See Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.
Listed Industrial Control Equipment
N223
Certified Process Control Equipment
Certified for use in Class I, Division 2, Groups A, B, C, D or
nonhazardous locations
Marked for all applicable acts
Marked for all applicable directives