22 Blow-molding Module

Publication 1746-IN014B-EN-P - January 2001

Wiring a Continuous-extrusion Machine

This setup has four identical injection units. Wire all four channels the same with
these I/O devices:

analog output to the valve amplifier for the parison die head

LVDT position input from the parison die head

Wiring a Reciprocating Screw Machine with Single Accumulator

This setup has a single accumulator driving four identical injection units. Wire all
four channels the same (see continuous extrusion, above) with these I/O devices:

analog output to the valve amplifier for the parison die head

LVDT position input from the parison die head

Wire the actuator for analog I/O signals from a fast-analog I/O module such as
1746-FIO4V (for voltage-level signals) in the SLC I/O chassis.

IMPORTANT

If multiple power sources can be used, do not exceed the
specified isolation voltage.

Servo Valve
and Hydraulic
Cylinder

LVDT

Valve
Amp

36

35

28

27

38

37

32

31

34

33

24

23

26

25

30

29

same wiring
as Axis 2

Axis 3

Axis 1

Axis 4

Axis 2

same wiring
as Axis 2

same wiring
as Axis 2