Downloading file, Downloading file -3, Using the path shown below – Rockwell Automation 1747-PBASE BASIC Development Software Programming Manual User Manual
Page 103
Publication 1746-PM001A-US-P
Communicating with the Module 9-3
Downloading File
After you have created and translated your program, your next step is to download
the translated version to the module. Downloading is performed from the BASIC
Development Software while in Terminal mode. Access the Terminal mode as
discussed in the previous section.
Programs can be downloaded using RS-232 or DH485 communications from your
personal computer. If DH485 communications are desired, an adapter is available
that converts RS-232 into DH485. (Refer to the SLC 500 BASIC and BASIC-T
User Manual, publication number 1746-UM004A-US-P.)
1. Select
Download from host to module
using the path shown below:
Path: Toplevel Menu
→
→
→
→
teRminal
→
→
→
→
File
→
→
→
→
Download from host to
module
Path: Main Menu
→
→
→
→
Other
→
→
→
→
teRminal
→
→
→
→
File
→
→
→
→
Download from host
to module
QuickStroke: Toplevel Menu
→
→
→
→
teRminal
→
→
→
→
[Page Down]
You are prompted for a filename to download as shown on the following
screen.
Figure 9.1 File to Download Screen
STRING INPUT: Next field
↓
>
File Setup Display deBug Exit
↓↑→←
to Edit
PBASE RS-232 TERMINAL MODE Version x.xx
+-----------------FILE TO DOWNLOAD------------------+
|Filename: DEBUG.BAS |
| |
|+=======Directory List=========+ |
||Select this field to get | OK
||a directory listing. | |
|| | Cancel
|| | |
|| | |
|| | |
|| | Help
|| | |
|| | Sort |
|| | |
|| | |
|+==============================+ |
| |
+===================================================+