Environmental specifications, Input specifications, Environmental specifications input specifications – Rockwell Automation 1746-NI8 SLC 500 Analog Input Modules User Manual User Manual
Page 77
Variable Content
TTL:Chap
A–2
Publication 1746Ć6.8 - April 1997
Description
Specification
Operating Temperature
0
°
C to 55
°
C (32
°
F to 131
°
F) in any slot except slot 0
0
°
C to 60
°
C (32
°
F to 140
°
F) in right most slot of chassis
Storage Temperature
-40
°
C to
+
85
°
C (-40
°
F to
+
185
°
F)
Relative Humidity
5% to 95% (without condensation)
Certification
UL listed
CSA approved
CE compliant for all applicable directives
Hazardous Environment Classification
Class I Division 2 Hazardous Environment
Description
Specification
Type of Input (Selectable)
"
10V dc
1-5V dc
0-5V dc
0-10V dc
0-20 mA
4-20 mA
"
20 mA
0-1 mA
Type of Data (Selectable)
Engineering Units
ScaledĆforĆPID
Proportional Counts (-32,768 to +32,767 range)
Proportional Counts (User Defined Range, Class 3 only)
1746ĆNI4 Data Format
Input Impedance
1 MW
Voltage Input (maximum)
±
30V between any two signal terminals
Current Input (maximum)
±
30 mA
Time to Detect Open Circuit
1 module scan
Input Step Response
See Chapter 4, Channel Filter Frequency Selection, page
4-7
Input Resolution
1 mV or 1
µ
A
Display Resolution
1 mV or 1
µ
A
Overall Module Accuracy
(0
°
C to 60
°
C, 32
°
F to 140
°
F)
Voltage input types (
"
10V dc, 1-5V dc, 0-5V dc, 0-10V dc):
±
0.1%
Current input types (0-20 mA, 4-20 mA,
"
20 mA):
±
0.05%
Current input type (0-1 mA):
±
0.5%
Overall Module Drift
Voltage input type:
±
6 ppm/
°
C
Current input type:
±
12 ppm/
°
C
Module Update Time
See Chapter 4, Update Time, page
4-5
Channel TurnĆOn Time
See Chapter 4, TurnĆOn Time, page
4-6
Channel TurnĆOff Time
See Chapter 4, TurnĆOff Time, page
4-6
Channel Reconfiguration Time
See Chapter 4, Reconfiguration Time, page
4-6
Environmental Specifications
Input Specifications