Module location in chassis, Modular chassis considerations, Fixed expansion chassis considerations – Rockwell Automation 1746-NI8 SLC 500 Analog Input Modules User Manual User Manual
Page 23
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
∇
∇
IA4
IA8
IA16
IM4
IM8
IM16
OA8
OAP12
OA16
IB8
IB16
IC16
ITB16
ITV16
IV8
IV16
IG16
OV8
OV16
OB8
OBP8
OBP16
OVP16
OG16
OW4
OW8
OW16
IO4
IO8
IO12
NI4
NI8
NIO4I
FIO4I
FIO4V
NIO4V
NT4
NR4
HSTP1
IH16
DCM
HS
OB16
IN16
BASn
BAS
OB32
OV32
IV32
IB32
OX8
NO4I
NO4V
KEn
KE
Ć
Ć
Ć
Ć
Ć
Ć
Ć
Ć
Ć
Ć
Ć
Ć
Ć
Ć
Ć
Ć
Ć
Ć
Ć
Ć
Ć
Ć
Ć
Ć
0.045
0.090
0.180
0.025
0.045
0.070
0.085
0.100
0.145
0.150
0.120
0.115
0.040
0.050
Ć
Ć
Ć
Ć
Ć
Ć
0.125
0.040
Ć
Ć
Ć
Ć
0.090
0.195
0.145
0.125
0.040
0.035
0.050
0.085
0.035
0.050
0.085
0.185
0.370
0.370
0.050
0.085
0.085
0.085
0.085
0.050
0.085
0.140
0.135
0.270
0.135
0.135
0.250
0.250
0.180
0.045
0.085
0.170
0.030
0.060
0.090
0.025
0.200
0.055
0.055
0.055
0.055
0.060
0.050
0.200
0.085
0.360
0.300
0.280
0.085
0.150
0.150
0.452
0.452
0.106
0.106
0.085
0.055
0.055
0.150
0.150
5V dc
(Amps)
24V dc
(Amps)
NI8
Fixed Controller Compatibility Table
3–2
Installation and Wiring
Publication 1746Ć6.8 - April 1997
Modular Chassis Considerations
Place your 1746-NI8 module in any slot of an SLC 500 modular, or
modular expansion chassis, except for the extreme left slot (slot 0) in
the first chassis. This slot is reserved for the processor or adapter
modules.
Important: For applications using the upper limit of the operating
temperature range, the 1746-NI8 module (or multiple
1746-NI8 modules) should be placed in the right most
slot(s) of the chassis. The specification for operating
temperature is:
Operating Temperature Range
0
°
C to 55
°
C (32
°
F to 131
°
F) in any slot except slot 0
0
°
C to 60
°
C (32
°
F to 140
°
F) in right most slot of chassis
Fixed Expansion Chassis Considerations
Important: The 2-slot, SLC 500 fixed I/O expansion chassis
(1746-A2) will support only specific combinations of
modules. If you are using the 1746-NI8 module in a
2-slot expansion chassis with another SLC I/O or
communication module, refer to the table at the left to
determine whether the combination can be supported.
In the table:
A dot indicates a valid combination.
No symbol indicates an invalid combination.
A triangle indicates an external power supply is
required. (Refer to the Analog I/O Module User
Manual, publication 1746-6.4.)
When using the table, be aware that there are certain
conditions that affect the compatibility characteristics of
the BASIC module (BAS) and the DH-485/RS-232C
module (KE).
When you use the BAS module or the KE module to
supply power to a 1747-AIC Link Coupler, the Link
Coupler draws its power through the module. The
higher current drawn by the AIC at 24V dc is calculated
and recorded in the table for the modules identified as
BASn (BAS networked) or KEn (KE networked).
Make sure to refer to these modules if your application
uses the BAS or KE module in this way.
Module Location in Chassis
•
∇