beautypg.com

Chapter, Technical specifications, Ossd response times – Rockwell Automation 442L-SFZNMN SafeZone Mini Safety Laser Scanner User Manual User Manual

Page 57

background image

Rockwell Automation Publication 10000337275 Ver 01—October 2014

55

Chapter 12

Technical specifications

Chapter

12

Technical specifications

Fig. 48: Diagram scanning range

2 meter SafeZone Mini

Fig. 49: Diagram scanning range

3 meter SafeZone Mini

OSSD response times

The total response time of your application is dependent on …

The basic response time of the SafeZone Mini.

The multiple sampling set.

The OSSDs used.

The control inputs used.

500

5

0.1

0.2

0.5

1

2

50

20

10

1

2

5

10

20

50

100

200

Reflectors > 2000%
Reflective films > 300%

White plaster

Writing paper

Grey cardboard

Matte black paint

Black shoe leather

Re

mi

ss

ion (

%

)

Protective field

Warning field

Scanning range [m]

500

5

0.1 0.2

0.5

1

2

50

20

10

1

2

5

10

20

50

100

200

Reflectors > 2000%
Reflective films > 300%

White plaster

Writing paper

Grey cardboard

Matte black paint

Black shoe leather

Re

mi

ss

ion (%)

Protective field

Warning field