beautypg.com

Rockwell Automation 442L-SFZNMN SafeZone Mini Safety Laser Scanner User Manual User Manual

Page 47

background image

Rockwell Automation Publication 10000337275 Ver 01—October 2014

45

Chapter 7

Application examples and connection diagrams

Two SafeZone Mini safety laser scanners with GSR DI

Fig. 45: SafeZone Mini in

combination with a GSR DI safety relay

Two SafeZone Mini safety laser scanners connected to a GSR DI safety relay. The GSR DI is configured for monitored manual
reset. SafeZone Mini scanners are configured for ON/OFF.

Power
In1
In2
Out
Logic

A2

A1

+

-

S11

S21

S12

S22

S32

S42

L12

L11

Y32

S34

13

14

23

24

24VDC

IN1

DI

IN2

0

1

2
3

4

5

6

7

8

LOGIC

Test Out

Reset

M

24V DC

0V DC

SafeZone Mini

SafeZone Mini

Shld
wire

Shld
wire

Wht*

Brn

Brn

Grn* Yel*

Gry

Gry

Pnk

Pnk

Blu

Blu

K1

K2

L1 L2 L3

K1

K2

Monitored Manual Reset

Color Pin Signal

Wht 1 Output-Warning Field1*
Brn 2 +24V DC
Grn 3 Universal I/O1*
Yel

4 Universal I/O2*

Gry 5 OSSD 1
Pnk 6 OSSD 2
Blu

7 0V DC

Shld 8 Earth Ground
* not configured for

this application
no connection

Wht* Grn* Yel*