Configuration connection m8 × 4 (serial interface) – Rockwell Automation 442L-SFZNMN SafeZone Mini Safety Laser Scanner User Manual User Manual
Page 43
Rockwell Automation Publication 10000337275 Ver 01—October 2014
41
Chapter 6
Electrical installation
Core assignment of the SafeZone Mini extension cable
Table 10: Core assignment of the
SafeZone Mini cable
Universal I/O connections of the SafeZone Mini
Do not use the universal I/O connection outputs for safety-related tasks!
The universal I/O connection outputs are purely application diagnostics outputs, e.g. for the transfer of information to
controllers.
Configuration connection
M8 × 4 (serial interface)
Fig. 39: Pin assignment configuration
connection M8 × 4
Table 11: Pin assignment configuration
connection M8 × 4
Notes
After configuration always remove the connecting cable from the configuration connection!
After the configuration of the device has been completed, locate the attached protection cap to cover the
configuration connection.
Core
Color
Function
1
White
Output for warning field 1
2
Brown
Supply voltage 24V DC
3
Green
Universal I/O connection 1
4
Yellow
Universal I/O connection 2
5
Gray
Output signal switching device OSSD1
6
Pink
Output signal switching device OSSD2
7
Blue
Supply voltage 0V DC
8
FE/shield
Functional earth/shield
ATTENTION
4
1
2
3
Pin
SafeZone Mini
PC-side RS-232-DSub
1
Reserved
Not assigned
2
RxD
Pin 3
3
0V DC (voltage supply)
Pin 5
4
TxD
Pin 2