Rockwell Automation 442L-SFZNMN SafeZone Mini Safety Laser Scanner User Manual User Manual
Page 55
Rockwell Automation Publication 10000337275 Ver 01—October 2014
53
Chapter 11
Diagnostics
Table 15: Error and status indications on the
sevensegment display
Display
Possible cause
Rectification of the error
Power-up cycle — all
segments are activated
sequentially.
No error
Object in protective field
No error
Object in warning field 1
No error
Object in warning field 2
No error
Initialization of the device
The display goes out automatically when the SafeZone
Mini has been initialized and/or the connection to the
second device has been made.
If the display does not go off:
Check whether the partner device is in operation.
Check the wiring.
If no partner device is connected:
Check the system configuration with the aid of the SCD
software. Transfer the corrected configuration to the
SafeZone Mini again.
Waiting for configuration or
configuration not completed
The display goes off automatically once the
configuration has been successfully transferred.
If the display
does not go off:
Check the system configuration with the aid of the SCD
software. Transfer the corrected configuration to the
SafeZone Mini again.
Waiting for restart of the device
Switch off the voltage supply for the SafeZone Mini for at
least two seconds and then switch it back on.
or
Error of the external device
monitoring (EDM)
Check whether the contactors are working correctly or if
they are wired incorrectly and rectify any error.
If
is displayed: also switch off the voltage supply
for the SafeZone Mini for at least two seconds and switch
it back on.
Error in the control switch for
restart or reset
Check the functionality of the control switch. The button
may be defective or permanently operated.
Check the wiring of the control switch for short-circuit to
24 V.
SafeZone Mini has a
malfunction or is faulty
Switch off the voltage supply for the SafeZone Mini for at
least two seconds and then switch it back on.
If the display does not go off:
Send the SafeZone Mini to the manufacturer for repair.
Overcurrent on OSSD
connection 1
Check the switching element connected (contactor,
relay). Replace, if necessary.
Check the wiring for short-circuit to 0V.
Short-circuit to 24V at OSSD
connection 1
Check the wiring for short-circuit to 24V.
Short-circuit to 0V at OSSD
connection 1
Check the wiring for short-circuit to 0V.
Display
Possible cause
Rectification of the error
Overcurrent on OSSD
connection 2
Check the switching element connected (contactor,
relay). Replace, if necessary.
Check the wiring for short-circuit to 0V.
Short-circuit to 24V at OSSD
connection 2
Check the wiring for short-circuit to 24V.
Short-circuit to 0V at OSSD
connection 2
Check the wiring for short-circuit to 0V.
.
.
.
.
.
.
.
.
.
.