Supplement Z

R

for measurement errors caused by reflection

With retroreflectors in the background at a distance of less than 1 m (39.4 in.) from the boundary of the protective field,
the supplement Z

R

is 200 mm (7.87 in.).

Supplement Z

F

due to lack of ground clearance

This supplement is necessary because a person is generally detected above the foot and the braking action can therefore
not take into account the length of the foot in front of the detection point. If a vehicle has no ground clearance, a person
may receive foot injuries.

Fig. 22: Supplement due to lack of ground clearance

 The flat rate supplement for ground clearance below 120 mm (4.7 in.) is 150 mm (5.91 in.). This supplement can be

further reduced in specific cases. For this purpose read off the actual supplement necessary for the ground clearance of
your vehicle from the diagram below:

Fig. 23: Diagram of ground clearance of the vehicle

Protective field width

The width of the protective field must cover the width of the vehicle and the supplements for the measurement error and
the lack of ground clearance.

How to calculate the protective field width S

B

(see EN ISO 13855):

 Calculate the protective field width S

B

using the formula:

S

B

= F

B

+ 2 × (Z

G

+ Z

R

+ Z

F

)

Where …
F

B

= Vehicle width

Z

G

= General safety supplement of the SafeZone Mini = 100 mm (3.94 in.)

Z

R

= Supplement for any reflection related measurement error of the SafeZone Mini

Z

F

= Supplement for any lack of ground clearance of the vehicle

SafeZone Mini

Protective field length

Ground clearance

2

F

120

60

50

0

50

100

150

Supplement 2

F

in mm

Gr

ound c

lear

anc

e

of the

ve

hi

cl

e i

n m

m

S

A