Chapter 7
Application examples and connection diagrams
SafeZone Mini with restart interlock and external device monitoring
Fig. 43: Connection diagram for
SafeZone Mini with
restart interlock and
external device monitoring
SafeZone Mini in conjunction with relays/contactors; operating mode: with restart interlock (universal I/O 1 must be
configured as reset) and external device monitoring (universal I/O 2 must be configured as EDM).
SafeZone Mini in combination with a GSR SI safety relay
Fig. 44: Connection diagram for
SafeZone Mini in combination
with a GSR SI safety relay
SafeZone Mini in combination with a GSR SI safety relay: operating mode of SafeZone Mini is ON/OFF and GSR SI is
configured for monitored manual reset.
SafeZone Mini
Shld
wire
Brn
Yel***
Grn**
Blu
Gry
Pnk
Wht*
Color Pin Signal
Wht
1
Output - Warning Field1*
Brn
2
+24V DC
3
Universal I/O1** (Reset)
Yel
4
Universal I/O2*** (EDM)
Gry
5
OSSD 1
Pnk
6
OSSD 2
Blu
7
0V DC
Shld
8
Earth Ground
Reset
K1
K2
K1
K2
* Not configured for this application
*
No Connection
** Software Configured for Reset input
*** Software Configured for EDM
+24V DC
0V DC
L1
M
L2 L3
K1
K2
Grn
A2
A1
+
-
S11 S21 S12 S22
L11 Y32 S34 13
13
14
14
23
23
24
24
24VDC
IN1
SI
RESET 0
MM
AM
K2
Reset
K1
K2
M
24V DC
0V DC
Monitored Manual Reset
SafeZone Mini
Shld
wire
Brn
Yel*
Grn*
Blu
Gry Pnk
Wht*
Color
Wht
Brn
Grn
Yel
Gry
Pnk
Blu
Shld
Pin
1
2
3
4
5
6
7
8
Signal
Output-Warning Field1*
+24V DC
Universal I/O1*
Universal I/O2*
OSSD 1
OSSD 2
0V DC
Earth Ground
* not configured for this
application
no connection
L1 L2 L3
K1