beautypg.com

Security door controls, Replacement of glass rod – SDC 491 EMERGENCY DOOR RELEASE User Manual

Page 2

background image

INSTALLATION INSTRUCTIONS

492 PULL STATION EMERGENCY DOOR RELEASE

P:\INSTALLATION INST\Accessories\INST-492.vsd REV A Page 1 07-08

Any suggestions or comments to this instruction or

product are welcome. Please contact us through

our website or email [email protected]

INSTALLERS NOTE;

The station is supplied with the glass rod removed. It is
recommended that the station be activated and tested prior
to installation of the glass rod.

Glass Rod and Hardware are shipped in the station box.

REPLACEMENT OF GLASS ROD;

Use an Allen wrench to open front cover of station. Remove
the glass debris from broken rod, then reset T-Handle to the
normal position.

To replace Glass Rod, insert one end of Rod under Spring
Tab. Then, with one finger lift other end of Spring Tab
allowing Glass Rod to slip into place.

TO CLOSE STATION;

ELECTRICAL SPECIFICATIONS;

Switch Contacts:

DPDT 10A @ 125vac

Buzzer:

12/24vdc @ 10/20ma

5

1

6

2

7

3

8

4

N/O

N/C

N/O

N/C

Terminal
Block A

Terminal

Block B

Micro
Switch B

Micro

Switch A

Buzzer Power

Supply

12/24vdc

-

+

OPTIONAL;
Back box model #492-BB available for
surface mount

Replacement Glass Rod #492-GL4

SECURITY DOOR CONTROLS

801 Avenida Acaso, Camarillo, CA 93012 • (805) 494-0622 • Fax: (805) 494-8861