Programming

Typical Wiring

P:\INSTALLATION INST\Push and Key Switch\INST-463U.vsd REV A 01-14 Page 2

Connecting To A Keypad Controlled Fail-Safe OR Fail-Secure Locking Device:

RELAY

FAIL

SECURE

LOCK

+

-

FAIL

SAFE

LOCK

+

-

To 12/24VDC

Power Supply*

*NOTE: Button, Keypad & Lock power are the same voltage. Refer to manufacturer’s
installation instructions for Power Supply, Keypad, & Lock wiring.

-

+

For Fail-Safe Only

For Fail-Secure Only

463U

-

1

2

3

4

5

COM N.O.

N.C.

+

+

-

5

12/24V

N.C.

N.O.

REX

COM

RELAY

TYPICAL KEYPAD

-

1

2

3

4

5

COM N.O.

N.C.

+

Connecting To An Access Control Panel
or Door Operator:

RELAY

463U

12-24 VDC

To Security

System

To Power

Supply

N.O.

N.C.

COM

_

+

Use the DIP switches to adjust the Relay Activation Time or to reverse the Standby Illumination setting.

O

N

1

2

3

4

O

N

RELAY

463U

-

1

2

3

4

5

COM N.O.

N.C.

+

1

ON

ON

2

ON

ON

3

ON
ON

4

Dip Switch #

Programming Feature

5 second unlock delay
10 second unlock delay
20 second unlock delay
Toggle ON/OFF
Standby Illumination

*

Relay Activation Time – Controlled by DIP switches #1, 2 & 3. DIP switches are additive.
For example, DIP switches #1 & 2 in the ON position equals 15 seconds.
Minimum Time (DIP switches 1, 2 & 3 are OFF) = 1 second
Maximum Time (DIP switches 2 & 3 are ON) = 30 seconds

Standby Illumination Status – controlled by DIP switch #4.
SW #4 OFF = Red (Idle); Flashing Green (Relay Active)
SW #4 ON = Green (Idle); Flashing Red (Relay Active)

*