Security door controls, Typical wiring, Electrical specifications – SDC 420 SERIES PUSH SWITCH User Manual
Page 4
![background image](/manuals/572436/4/background.png)
BLU
VIO
YEL
WHT
ORG
This push to exit button is specifically intended for installation on Access Controlled Egress doors as described in the Boca
code. A motion detector is the primary means of releasing a magnetic lock on the door. The push to exit button is intended,
as a back up means of releasing the lock in the event there is a problem with the motion detector. When the button is
pressed, the lock releases for 30-seconds. If pressed again during the 30-seconds lock release period, the unit will
“Retrigger” starting a new 30-second lock release period.
INSTALLATION INSTRUCTIONS
MODEL 413MN & 423M PUSH SWITCH
FIXED 30 SECOND TIME DELAY
P:\INSTALLATION INST\Push and Key Switch\INST-413M-423M.vsd REV D 02-13 Page 1
Any suggestions or comments to this instruction or
product are welcome. Please contact us through
our website or email [email protected]
SECURITY DOOR CONTROLS
801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 • Fax: (805) 494-8861
www.sdcsecurity.com • E-mail: [email protected]
413MN
423M
1
2
7
4
3
8
6
5
9
0
*
#
PUSH
EXIT
TO
ACCESS
CONTROL
MODEL 413MN/423M
PUSH TO EXIT
SWITCH
POWER
SUPPLY
MOTION
DETECTOR
EMLOCK
413MN OR 423M
MANUAL RELEASE DEVICE
C
NC
NO
ACCESS CONTROL
V+
NO V-
C
NC
NO
C
NC
MD-31D
FAIL SAFE
REQUEST-TO-EXIT
SENSOR DEVICE
+
-
POWER
FAIL-SAFE LOCK
-
POWER
SUPPLY
+
12/24VDC
TYPICAL WIRING
BLK
RED
WHT/BLK
ORG/BLK
NO
COM
NC
NO
COM
NC
+
-
TIMER
POWER
YEL/BLK
LED
A
B
Electrical Specifications
Input Voltage : 12/24VDC @90ma.
LED Indicator : 12/24VDC @ 10/20ma
Output Relay: DPDT
Max Load : 30VDC @ 5 AMP (Resistive)