SDC 1490A Bolt Lock, Super Narrow User Manual
Security door controls, Installation instructions 1490a
SECURITY DOOR CONTROLS
801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 • Fax: (805) 494-8861
www.sdcsecurity.com • E-mail: [email protected]
INSTALLATION INSTRUCTIONS
1490A
OVERHEAD INSTALLATION HORIZONTAL
1.
Examine the top rail of the door for the most suitable location for the strike. Mark the door for the end of the strike closest to
the lock stile, and make a corresponding mark on the header to line up with the first mark.
2.
Locate center line of door thickness on the header and use the Template Sheet to determine the header and door cut-outs.
SIDE JAMB INSTALLATION VERTICAL
3.
Examine the lock stile jamb for the point nearest the center of the door height, with space available for the lock and strike.
Mark the door stile horizontal for the top end of the strike and make a corresponding mark on the jamb.
4. Locate center line of door thickness on the jamb and use Template Sheet to determine the cut-out to jamb, lining up the top
of the cutout with the horizontal mark on the jamb. Center punch the tab mounting screw locations and counter sink for #10
screw. Saw or rout the cutout 1.26” x 8”.
5. Attach the mounting tabs inside.
6.
Attach power supply leads to lock leads. Handle the lock carefully; do not hang it by the wire leads. Insert wires into the
header cavity carefully so they do not interfere with proper locating of the lock in the cutout.
7.
Insert lock. Horizontally, the bolt end is nearest the lock stile. Vertically, the bolt must be at the top end of the cutout.
Secure with #10-32 machine screw.
8.
Using strike for a template, mark screw hole location on door and drill holes for screws supplied. Mortise as required.
Attach strike.
9.
The automatic relock switch is set for 1/8” clearance between the top of the door and transom bar or head jamb. Any
additional gap may be compensated for by loosening the lock nut and turning the switch assembly clockwise until proper
adjustment is reached. Be sure to tighten lock nut when adjustment is satisfactory.
1. Mortise cutout in
tube for face plate
(fits flush with
surface of tube).
2. Position screws
for attaching
tabs, drill holes,
attach tabs.
4. Slide lock into
position, attach
to tabs.
3. Connect wiring
to lock.
Easy Installation or Servicing
All Space Saver locks are
easily installed in any existing
entrance merely by mortising
out a cutout, attaching the
wiring, inserting the lock, and
bolting it into position with two
attaching tabs. Cutting studs is
no
longer
a
problem
or
expense.
Any suggestions or comments to this instruction or
product are welcome. Please contact us through
our website or email [email protected]
P:\INSTALLATION INST\Electric Bolt Locks\INST-1490A\INST-1490A.vsd REV -
05-09 Page 1
Fig. 2
Auto Relock Switch
Adjustable for Wide Door Gap
Loosen nut.
Turn assembly
clockwise for wide
door gap.
Tighten nut.
Fig. 1