SDC 1190 SERIES Bolt Lock, Narrow User Manual
Page 2
P:\INSTALLATION INST\Electric Bolt Locks\INST-90 DEG Dual Coil\INST-90 DEG.vsd REV E 06-13 Page 2
1190A
Face plate: 8” x 1-1/2” x 0.125”
(203.2mm x 38.1mm x 3.175mm)
I.D. Requirements: 8” x 1-1/2” x 1-1/2”
(203.2mm x 38.1mm x 38.1mm)
Solenoid: Continuous duty
Standard voltage: 24VDC @ .7 Amp
Strike: M-Mortise 4” x 1-1/2” x 0.125” (101.6mm x 38.1mm x 3.175mm)
Bolt: 3/4” (6.35mm) dia. S.S., 3/4” (6.35mm) throw
1091A/1091ADL (DEADLOCKING)
Face plate: 8” x 1-1/2” 0.125” (35.1mm x 35.1mm x 3.175mm)
1091STA: 4-7/8” x 1-1/4” x 0.0937” ANSI
(123.53mm x 31.75mm x 2.28mm)
I.D. Req. 8” x 1-1/2” x 1-1/2”
(203.2mm x 38.1mm x 38.1mm)
Solenoid: Continuous duty
Dual Voltage:
12VDC @ .9 AMP
24VDC @ .45 AMP
Strike: M-Mortise 4” x 1-1/2” x 0.125” (101.6mm x 38.1mm x 44.45mm)
Bolt: 5/8” (15.88mm) dia. S.S., 3/4” (6.35mm) throw
FOR FS23M AND 1091A/1091ADC:
FS23M
Face plate: 8” x 1-1/2” x 1/8”
(203.2mm x 38.1mm x 3.175mm)
I.D. Requirements: 8” x 1-1/2” x 1-1/2”
(203.2mm x 38.1mm x 38.1mm)
Solenoid: Continuous duty
Dual Voltage:
12VDC@ .9 Amp
24VDC@ .45 Amp
Strike: M-Mortise 4” x 1-1/2” x 0.125” (101.6mm x 38.1mm x 3.175mm)
For wood 1-3/4” deep (44.45mm)
Bolt: 5/8” (15.88mm) dia. nylon with magnet insert, 5/8” (15.88mm)
throw.
Red pilot lamp standard to indicate door locked.
FOR 1190A ONLY:
DOOR IS SHOWN CLOSED AND LOCKED.
UNLOCKING MAY BE CONTROLLED BY
MULTIPLE SWITCH LOCATIONS.
RED
POWER
N.C.
ACCESS CONTROLS
N.O.
A.R.S.
YEL
YEL
WHT
N.C.
TROUBLE SHOOTING
Problem
Solution
Bolt does not project
Check voltage and alignment
of strike.
Bolt projects but chatters
Voltage too low.
Bolt will not retract
Strike misaligned
BOLT POSITION SENSOR (MAGNETIC)
B
Indicates bolt locked or unlocked
.25 Amp
DOOR POSITION SWITCH (MECHANICAL)
D
Indicates door opened or closed
5 Amp
ARS
YEL
YEL
12 VDC CONFIGURATION
RED
BLK
BLU
WHT
YEL
YEL
RED
BLK
BLU
WHT
24 V CONFIGURATION
RED = N/C
WHT = COM
BLU = N/O
CONTACT RATING
5 AMPS @ 125 VAC
RED = N/C
WHT = COM
BLU = N/O
DPS
DPS / BPS CONFIGURATION
BP
S