FIGURE 7
FIGURE 8
P:\INSTALLATION INST\ELECTROMAGNETIC LOCKS\INST-SHEAR 61-62\INST-SHEAR 61-62.vsd REV F 01-13 Page 5
DPS OPTION
YEL = N/O
GRY = COM
ORG = N/C
BAS OPTION
WHT = N/O
BLK = COM
RED = N/C
Please note the drawing in
Fig. 1. It show two different
alignments off center of the
shear tab.
For normal single acting and
double acting door alignment
see Fig. 2.
For slightly warped single
acting doors see Fig. 4.
This also works well for quick
release, when switch bars
are used.
The offset shear tab cannot
be used on shear locks with
bond sensors.
To Fused 12V or 24V
DC Power Source
To Fused 12V or 24V
DC Power Source
LOCK
red/blk
wht/blk
ACCESS
CONTROL
+
-
TDA
Figure B
Model 1562 – With built in
Auto Relock Switch and
Auxiliary Auto Relock Delay
Timer Board
Model 1561 – With built in
Auto Relock Switch Auto
Relock Delay Timer
red/blk
wht/blk
+
-
Figure A
LOCK
ACCESS
CONTROL
Fig. 1
006-001-04A
.343
.312
wide
wide
Fig. 3
006-001-04A
Offset shear tabs
ARMATURE TOP VIEW
ARMATURE SHEAR TAB
INSTALLATION
Fig. 4
006-001-04A
Fig. 2