beautypg.com

Steps 1 & 2 step 3 – SDC E6200 SERIES MAGNETIC LOCK User Manual

Page 2

background image

P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E6200.vsd REV -

07-10 Page 2

1. Fold template as indicated on dotted line. For single doors locate template against the door and header on the
lock jamb side of the frame.

2. Mark and drill holes as indicated by the template.

3. Mount armature to door.

STEPS 1 & 2

STEP 3

N/C

N/O

COM

YEL

GRN

ORG

COMMON

GOOD BOND

NO/POOR BOND

WIRE

COLOR

CONTACT

DESCRIPTION

BOND SENSOR (BAS) WIRING

To Properly
Fused DC Power
source

(-)

(+)

* ACCESS CONTROL(S)

E6200 EMLOCK

BLU
BLK
BRN

RED

(+)

(-)

24VDC @ .125 Amps

To Properly
Fused DC Power
source

(-)

(+)

* ACCESS CONTROL(S)

E6200 EMLOCK

BLU

BRN

BLK

RED

(+)

(-)

12VDC @ .250 Amps

24VDC CONFIGURATION

12VDC CONFIGURATION

N/C

N/O

COM

WHT

GRY

VIO

COMMON

ACTIVATE WHEN DOOR

OPEN

ACTIVATE WHEN DOOR

CLOSED

WIRE

COLOR

CONTACT

DESCRIPTION

DOOR POSITION SENSOR (DPS) WIRING

4. WIRING DETAILS: