Note:

Power the 100VDK devices using the MAIN OUTPUT terminals. The
zone controller cards are not required and can damage the latch
retraction units if used.

The low current draw of each device allows both devices to
operate simultaneously without the need for a sequencer.

KEY SWITCH

OR

ACCESS CONTROL

To AC Mains

EARTH GND

NEUTRAL
HOT

+ -

DC

Output

RED

SINGLE
DEVICE

BLK

VON DUPRIN POWER SUPPLY

MODELS

PS873 OR P914

To AC Mains

EARTH GND

NEUTRAL
HOT

MODELS

PS873 OR P914

+ -

DC

Output

RED

KEY SWITCH

OR

ACCESS CONTROL

(Controls Both Devices)

RED

BLK

BLK

PAIR

OF

DEVICES

VON DUPRIN POWER SUPPLY

P:\INSTALLATION INST\SWITCH KIT\INST-LR100VDK-22.vsd REV C 10-13 Page 3