Instruction sheet, Prs.4tec, Prescolite tollfree technical support – Prescolite SLOPED CEILING ADAPTORS User Manual
Page 2: Hours: 8am - 5pm et
www.prescolite.com
• Prescolite
TollFree
Technical
Support
1.888.PRS.4TEC
•
Hours:
8am
- 5pm
ET
701 Millennium Boulevard • Greenville, SC 29607
With representatives offices in principal cities throughout North America.
Copyright 2010, 02/10 revision, All Rights Reserved - Printed in U.S.A.
Part No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 01863200
Instruction
Sheet
1.
Place ceiling adaptor on housing plaster flange.
2.
Align MAJOR AXIS of ceiling adaptor with MINOR AXIS of
fixture housing.
3.
Use the (2) 9/64” dia holes in the ceiling adaptor as drill
guides to drill through the housing plasterplaster flange with
a 1/8” dia drill.
4.
Remove the ceiling adaptor from the housing plaster flange.
5.
Enlarge the (2) 1/8” dia drilled holes in the housing plaster
flange with a 3/16” dia drill.
6.
Replace ceiling adaptor on housing plaster flange. Realign
adaptor and housing per step 2 above and secure in place
with (2) 8-32 pan head self-tapping screws (included in
packet).
7.
Turn to page 4 and follow FIGURE 5 instructions.
FIGURE 2. (OLD METHOD) ATTACHMENT OF SCA3/5/6/8/10/12/13 CEILING ADAPTORS TO DIECAST ALUMINUM
PLASTER FLANGE HOUSINGS.
WET CEILING ADAPTOR
(FLANGELESS)
SLOPE OF CEILING
DRY CEILING ADAPTOR
(FLANGED)
8-32 PAN HEAD
SCREWS
HOUSING PLASTER FLANGE
MAJOR AXIS OF ADAPTOR
MINOR AXIS OF HOUSING
1) DRILL (2) 1/8” DIA. HOLES.
2) REMOVE ADAPTOR FROM PLASTER FLANGE.
3) USE 3/16” DIA. DRILL TO ENLARGE THE 1/8” DIA.
HOLES IN THE PLASTER FLANGE
1) DRILL (2) 1/8” DIA. HOLES.
2) REMOVE ADAPTOR FROM PLASTER FLANGE.
3) USE 3/16” DIA. DRILL TO ENLARGE THE 1/8”
DIA. HOLES IN THE PLASTER FLANGE
HOUSING PLASTER FLANGE
WET CEILING ADAPTOR
(FLANGELESS)
MINOR AXIS OF HOUSING
8-32 PAN HEAD SCREWS
SLOPE OF CEILING
DRY CEILING ADAPTOR
(FLANGED)
MAJOR AXIS OF ADAPTOR
FIGURE 2
FIGURE 3
FIGURE 3. ATTACHMENT OF SCA6/8 CEILING ADAPTORS TO STEEL PLASTER FLANGE ON 79/84 HOUSINGS.
(1/4”)
(1/4”)
1.
Remove light housing (not shown) from housing plaster
flange assembly.
2.
Place ceiling adaptor on housing plaster flange.
3.
Align MAJOR AXIS of ceiling adaptor with MINOR AXIS of
flange assembly.
4.
Use the (2) 9/64” dia. holes in the ceiling adaptor as drill
guides to drill through the housing plaster flange with 1/8”
dia. drill.
5.
Remove the ceiling adaptor from the housing plaster flange.
6.
Enlarge the (2) 1/8” dia drilled holes in the housing plaster
flange with a 3/16” dia drill.
7.
Replace ceiling adaptor on housing plaster flange. Realign
adaptor and flange assembly per step above and secure
in place with (2) pan head self-tapping screws (included in
packet).
8.
Reinstall light housing as required.
9.
Turn to page 4 and follow FIGURE 5 instructions.