Prescolite 6LCLEDWW User Manual
Instruction sheet, Installation instructions, Liteframe
Instruction
Sheet
www
.prescolite.com
Prescolite T
ollFree T
echnical Suppor
t
1.888.PRS.4TEC
Hours: 8am - 5pm ET
701 Millennium Blvd, Greenville, SC 29607
With representatives offices in principal cities throughout North America.
Copyright 2013, 10/17/13, All Rights Reserved - Printed in U.S.A.
Part No ....................................................... 93044255
Sheet 1 of 1
IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Follow label information and instructions
concerning Wet or Damp Locations, installation near combustible materials, insulation, building materials, and proper lamping. Do
not install in areas subject to combustible vapors or gases. Before wiring to power supply and during servicing or relamping, turn
off power at fuse or circuit breaker. All servicing or relamping must be performed by qualified service personnel.
Product must be grounded to avoid potential electric shock or other potential hazard. Product must be
mounted in locations and at heights and in a manner consistent with its intended use, and in compliance
with the National Electrical Code and local building codes. The use of accessory equipment not recommended by the
manufacturer or installed contrary to instructions may cause an unsafe condition. Do not block light emanating from product in
whole or part, as this may cause an unsafe condition. Do not allow items such as drapes, curtains, screens or the like to come into
contact with the product or to block light from the product, as this may cause an unsafe condition.
WARNING - This product contains chemicals known to the State of California to cause cancer, birth defects and/or other
reproductive harm. Thoroughly wash hands after installing, handling, cleaning, or otherwise touching this product.
CAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK, MAKE CERTAIN THAT
THE POWER SUPPLY IS OFF BEFORE INSTALLING OR SERVICING THIS FIXTURE!
1. Install the fixture in the ceiling using the hanger bars (supplied), or mounting channel or bars (by others) placed in the adjustable mounting
brackets. Mount the fixture in the ceiling so that the weight of the fixture is supported by the hanger bars, mounting channel, bar, and/or
hanger wires secured to the building structure.
2. Adjust the fixture so the bottom of the plaster flange opening is flush with the finished ceiling line and in alignment with adjacent fixtures.
Secure mounting brackets by tightening wing nuts on either side of the fixture.
3. Determine where the supply wiring conduit will enter the J-Box and attach it in conformance with the National Electric Code.
4. Remove J-Box cover plate. Remove appropriate knockout and assemble appropriate connector for the supply wire used. Connect ground
wires to green ground leads. Connect white (common) to white (leads). Connect power supply (line) to black lead(s). Reinstall J-Box cover.
WARNING: DO NOT pinch wires between J-Box/ballast cover and J-Box. Consult a qualified electrician for all other
options that require other wiring configurations.
5. Pull electrical cover (1) down through opening in fixture.
6. Insert connector (2) into connector (3) and snap firmly together.
7. Carefully put wires and connectors (2) & (3) into cover (1). Place tab (5) into slot of reflector (6) and screw (4) into hole in reflector (6). Make
sure there are not any wires pinched between item (1) and item (6). Tighten screw (4).
8. Squeeze two torsion springs (7) together and insert ends into two brackets (8). Push trim assembly up towards ceiling until springs draw trim
firmly against the ceiling.
KEEP THESE INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
LITEFRAME
®
LC6LED, 6LCLED, and 6LCLEDWW
1
2
3
4
7
5
SCREW ITEM 4
INTO THIS HOLE
8
6
Item 8 can be put
in other locations to
change orientation of
wall wash.
4
3
D
C
B
A
4
3
2
1
D
C
B
A
1
2
REV
DATE
RECORD
DESN CHCK
C
CRITICAL DIMENSIONS
UNSPECIFED TOLERANCES: INCHES
X.X=0.1 X.XX=0.03 X.XXX=0.010
FRACTIONS=1/32 ANGULAR TOLERANCE=1
CATALOG NO.
ENGINEERING:
CHECKED BY:
THIRD ANGLE PROJECTION
DRAWN BY:
DO NOT SCALE PRINT
CONFORMS TO ASME Y14.5M
DIMENSIONS IN [ ] IN MM
DIMENSIONS IN INCHES
This document contains confidential and proprietary information of
Prescolite. Receipt or possession of this document does not convey any
rights to reproduce or disclose its contents, or to make, use , or sell
anything it may disclose. Reproduction, disclosure, or use of the document
or its contents, without the specific written authorization of Prescolite, may
violate the intellectual property rights of Prescolite.
MATERIAL:
FINISH:
PART NO.
SCALE
SIZE
DRAWING NO.
REV.
1:2
csteadman
MDR
MDR
08/09/13
01/04/13
01/04/13
ASSY-LT ENG 6LCLED / P8104/5/6
93043805
E
SHT 3
4 SHTS
---
---
---
---
CLM
MDR
EC-130325011
04/29/13
D
MDR
CWW
EC-130710002
08/01/13
E
-
CAS
EC-
09/20/13
F
* SEE NOTES ON SHEET 4 *
150
ASSEMBLY FOR
6LCLED5WW / P8104 SERIES
6LCLED6WW / P8105 SERIES
10
20
40
50
60
70
80
90
130
100
LOCATE ITEM 60 AS SHOWN
SO WIRE LEADS ARE CLOSE
TO HOLE (NOT SHOWN) IN ITEM 70
LOCATE ITEM 30 AND ITEM 40
AS SHOWN SO WIRES ON
ITEM 60 ARE INSIDE OF NOTCHES
30
120 SEE DETAIL A
SEE DETAIL A
120
10
70
INSTALL ITEM 20 WITH
SMOOTH SIDE DOWN
160
DETAIL A
PRESS ITEM 10 UP
AND HOLD AGAINST
ITEM 70 WHILE
SLIDING ITEM 120
(3X) DOWN AGAINST
ITEM 70 ON ALL
THREE TABS OF
ITEM 10.
SEE NOTE 3
ON SHEET 4
110
75
80
6LCLED7WW / P8106 SERIES
6LCLED5WW / P8104 SERIES
6LCLED6WW / P8105 SERIES
ASSEMBLY FOR
6LCLED7WW / P8106 SERIES
ITEM 75 MOUNTS TO
ITEM 130 BY ITEM 80
AND IS INSIDE OF ITEM 70
FLANGE
OF ITEM 70
4
3
D
C
B
A
4
3
2
1
D
C
B
A
1
2
REV
DATE
RECORD
DESN CHCK
C
CRITICAL DIMENSIONS
UNSPECIFED TOLERANCES: INCHES
X.X=0.1 X.XX=0.03 X.XXX=0.010
FRACTIONS=1/32 ANGULAR TOLERANCE=1
CATALOG NO.
ENGINEERING:
CHECKED BY:
THIRD ANGLE PROJECTION
DRAWN BY:
DO NOT SCALE PRINT
CONFORMS TO ASME Y14.5M
DIMENSIONS IN [ ] IN MM
DIMENSIONS IN INCHES
This document contains confidential and proprietary information of
Prescolite. Receipt or possession of this document does not convey any
rights to reproduce or disclose its contents, or to make, use , or sell
anything it may disclose. Reproduction, disclosure, or use of the document
or its contents, without the specific written authorization of Prescolite, may
violate the intellectual property rights of Prescolite.
MATERIAL:
FINISH:
PART NO.
SCALE
SIZE
DRAWING NO.
REV.
1:2
csteadman
MDR
MDR
08/09/13
01/04/13
01/04/13
ASSY-LT ENG 6LCLED / P8104/5/6
93043805
E
SHT 3
4 SHTS
---
---
---
---
CLM
MDR
EC-130325011
04/29/13
D
MDR
CWW
EC-130710002
08/01/13
E
-
CAS
EC-
09/20/13
F
* SEE NOTES ON SHEET 4 *
150
ASSEMBLY FOR
6LCLED5WW / P8104 SERIES
6LCLED6WW / P8105 SERIES
10
20
40
50
60
70
80
90
130
100
LOCATE ITEM 60 AS SHOWN
SO WIRE LEADS ARE CLOSE
TO HOLE (NOT SHOWN) IN ITEM 70
LOCATE ITEM 30 AND ITEM 40
AS SHOWN SO WIRES ON
ITEM 60 ARE INSIDE OF NOTCHES
30
120 SEE DETAIL A
SEE DETAIL A
120
10
70
INSTALL ITEM 20 WITH
SMOOTH SIDE DOWN
160
DETAIL A
PRESS ITEM 10 UP
AND HOLD AGAINST
ITEM 70 WHILE
SLIDING ITEM 120
(3X) DOWN AGAINST
ITEM 70 ON ALL
THREE TABS OF
ITEM 10.
SEE NOTE 3
ON SHEET 4
110
75
80
6LCLED7WW / P8106 SERIES
6LCLED5WW / P8104 SERIES
6LCLED6WW / P8105 SERIES
ASSEMBLY FOR
6LCLED7WW / P8106 SERIES
ITEM 75 MOUNTS TO
ITEM 130 BY ITEM 80
AND IS INSIDE OF ITEM 70
FLANGE
OF ITEM 70
6LCLED5WW
6LCLED6WW
6LCLED7WW