Instruction Sht. No.. . . . . . . . . . . . . . . . . . . . . . . . 93037150

When installed according to the instructions provided and as specified in volume 1 of the UL Fire Resistance Directory,

Prescolite FT6QLIC

luminaire may be used in fire resistance Floor-Ceiling and Roof-Ceiling designs. See File

under Fire Classified Directory CDHW.

Follow this Instruction Sheet Carefully. Be sure Electricity is OFF before starting Installation.

Instruction

Sheet

WARNING 1: - If any special control devices are used with this fixture, follow the instructions carefully to assure full compliance with N.E.C. requirements.

If there are any questions, contact a qualified electrical contractor.

WARNING 2: Use only those trims, lamps and maximum wattages proper for this fixture, as indicated on the label within the fixture housing.

WARNING 3: The National Electrical Code, Article 110-3 (b), states that “Listed or Labeled equipment shall be used or installed in accordance with any

instructions included in the listing or labeling”. Use only with Prescolite UL listed trims. Use of other trims not listed in this fixture, including those that are

UL classified, is a violation of N.E.C. 110-3 (b) and voids all warranties.

WARNING 4: FT6 and FT6CF2H are type non-ic fixtures. Insulation must be kept at least 3” from fixture sides to prevent lamp cycling.

INStAllAtION INStRuCtIONS

Ft6QlIC

INStAllAtION IN WOOD JOIStS

1. Slip Bar Hangers (1) into channels in Plaster Frame (2). Hold Frame in desired position between Joists (3) and drive

Bar Hanger Tabs (4) into Joists. Use a minimum 1” lg. steel Nail or Screw (26) through holes in Bar Hanger ends for

additional support. Tighten bar hanger Locking Screws (5) in ends of Plaster Frame to prevent lateral movement of Plaster

Frame. (See Fig. 1 and 2)
2. Remove Cover Plate (9) from Junction Box (10). Slip Type NM Cable (Romex) (11) through desired hole in Junction

Box (10) above Retaining Plate (13). Cable (11) is secured by Retaining Plate (13). (See Fig. 3)
3. If other than Type NM Cable (Romex) is to be used, remove one Large Knockout (15) at desired location on top or

sides of Junction Box (10). Bring appropriate Electrical Supply Cable into Junction Box and secure in place with proper

UL listed Connector (NOT FURNISHED).
4. Connect Fixture Wires (27) to Supply Wires (16) as shown in Wiring Diagram. Use UL listed Wirenuts (NOT

FURNISHED).
5. After ceiling is finished lower Housing (6) until flush with Ceiling.
6. To gain access to Junction Box (10), after ceiling is finished, remove three Screws (24) that hold Housing (6) in place.

Lower the Housing. Remove Screw (21) and Access Door (22) located inside Fixture. Junction Box Cover Plate (9) can

now be removed for service.
7. Plaster Frame (2) and Gasket (25) must be in contact with Ceiling (23).
8. If joists are spaced greater than 16 inches on center, 2x4 (4 inch dimension vertical) or greater lumber shall be used

to span between joists at the plane of the ceiling to create a 16 inch on center space to mount the fixture as shown

in Fig. 4.

(Ceiling opening is to be 6 7/8” Diam.)

this instruction sheet is also intended to be used as a paint shield. Upon completion of installation, crumple this

sheet up and insert it up into the housing to protect the socket and labels from being spray painted.

IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Follow label information

and instructions concerning Wet or Damp Locations, installation near combustible materials, insulation, building materials,

and proper lamping. Do not install in areas subject to combustible vapors or gases. Before wiring to power supply and

during servicing or relamping, turn off power at fuse or circuit breaker.

All servicing or relamping must be performed by

qualified service personnel. Product must be grounded to avoid potential electric shock or other potential hazard.

Product must be mounted in locations and at heights and in a manner consistent with its intended use, and in

compliance with the National Electrical Code and local codes. The use of accessory equipment not recommended by

the manufacturer or installed contrary to instructions may cause an unsafe condition. Do not block light emanating from

product in whole or part, as this may cause an unsafe condition. Do not allow items such as drapes, curtains, screens or

the like to come into contact with the product or to block light from the product, as this may cause an unsafe condition.

WARNING: this product contains chemicals known to the State of California to cause cancer, birth defects, and/or other reproductive

harm. thoroughly wash hands after installing, handling, cleaning, or otherwise touching this product.