Board-mounted bank 2 settings – Omnitron Systems Technology iConverter 2FXM User Manual User Manual
Page 7

transmitting traffic to its link partner and store incoming frames from the other port in the internal buffer
until the congestion clears. If the internal buffer of the 2FXM becomes congested, it will transmit a Pause
frame to its link partner.
3.2.1.2
SW2 - Fiber Port 1 Full/Half-Duplex “FDX/HDX”
When the DIP-switch is in the Full Duplex “FDX” position (factory default), the fiber port will facilitate a
connection that supports Full-Duplex operation. Setting this DIP-switch to Half-Duplex “HDX” facilitates
a connection that supports only Half-Duplex.
3.2.1.3
SW3, SW4 - Reserved
These DIP-switches are for factory use only.
NOTE: DIP-switches marked Reserved must be kept in the LEFT (factory default) position.
3.2.1.5
SW5 - Fiber Port 2 Full/Half Duplex “FDX/HDX”
When the DIP-switch is in the Full Duplex “FDX” position (factory default), the fiber port will facilitate a
connection that supports Full-Duplex operation. Setting this DIP-switch to Half-Duplex “HDX” facilitates
a connection that supports only Half-Duplex.
3.2.1.6
SW6, SW7, SW8 - Link Modes
These three DIP-switches configure the link mode settings. The following table details possible Link Mode
DIP-switch configurations.
PI
SA
SW6
SW7
SW8
Result
Left
Left
Left
Enables Link Segment mode (LS).
Right
Left
Left
Enables Link Propagate mode (LP).
Left
Right
Left
Enables Remote Fault Detection mode plus
Link Segment mode (RFD+LS).
Right
Right
Left
Enables Remote Fault Detection mode plus
Link Propagation mode (RFD+LP).
Left
Left
Right
Enables Symmetrical Fault Detect mode (SFD).
Right
Left
Right
Illegal setting. LS mode is enabled.
Left
Right
Right
Illegal setting. LS mode is enabled.
Right
Right
Right
Illegal setting. LS mode is enabled.
SW6
SW7
SW8
Result
Down
Down
Down
Enables Link Segment mode (LS).
Up
Down
Down
Enables Link Propagate mode (LP).
Down
Up
Down
Enables Remote Fault Detection mode plus
Link Segment mode (RFD+LS).
Up
Up
Down
Enables Remote Fault Detection mode plus
Link Propagation mode (RFD+LP).
Down
Down
Up
Enables Symmetrical Fault Detect mode (SFD).
Up
Down
Up
Illegal setting. LS mode is enabled.
Down
Up
Up
Illegal setting. LS mode is enabled.
Up
Up
Up
Illegal setting. LS mode is enabled.
NOTE: Connecting two converters set to any of the RFD modes are illegal and will cause a “deadly
embrace” lockup.
NOTE: It is recommended to keep the LS setting (default) until initial configuration is complete.
For detailed information on the operation of the different Link Modes, download the application note
“iConverter Link Modes” available on Omnitron’s web page:
http://www.omnitron-systems.com/downloads.php
Page 7