“Incomplete”, Discovery is in process, but is not yet completed.
•
Multiplexer State - Indicates the Multiplexer state (“Discard”, “Forward” or “Unknown”) of the remote
ports. If “Forward” is displayed, the remote partner is forwarding non-OAMPDUs to the lower sublayer.
If “Discard”, the remote partner is discarding non-OAMPDUs network frames. If “Unknown”, the
Multiplexer state of the remote partner is indeterminate.
•
Parser Action - Indicates the Parser Action state (“Discard”, “Forward” or “Loopback”) of the remote
ports. If “Forward” is displayed, the remote partner is forwarding non-OAMPDUs network frames to
the higher sublayer. If “Loopback” is displayed, the remote partner is looping back non-OAMPDUs
network frames. If “Discard” is displayed, the remote partner is discarding non-OAMPDUs network
frames.
•
Critical Event - Indicates the Critical Event state (“Yes” or “No”) of the remote partner. If “Yes” is
displayed, the local device has detected a Critical Event. If “No”, the local device has not detected a
critical event.
•
Link Fault - Indicates the remote partner has detected a fault in the receive direction (“Yes” or “No”). If
“Yes” is displayed, the receive link is down. If “No”, the receive link is up.
•
OAM Mode - Indicates the OAM mode (“Active” or “Passive”) of the remote partner.
•
Supports - Indicates the supported options (Variable Access “Var”, Link Event Notification “Events”,
Loopback “LB”, or blank if no options are supported) of the remote partner.
•
OUI - Indicates the three hex byte IEEE organizational specific identifier (or blank if unknown) of the
remote partner.
802.3ah parameters can be accessed by selecting options 7 from the Port configuration screen. The fiber
(port 1) configuration screen is displayed.
PI
SA
802.3ah Control - iConverter 2FXM
iConverter, Serial Agent
Identifier -
Chassis Number = 1 Slot Number = 1 Model Number = 8959-0
Port # = 1
1: 802.3ah OAM State
Disabled
Local Status
2: OAM Mode
Passive
Discovery State
Incomplete
3: Loopback Mode
Disabled
Multiplexer State
Disabled
4: Loopback Timeout
30 sec
Parser Action
Unknown
5: Unidirectional Mode
Not Available
Remote Status
Discovery State
Unknown
Critical Event
Unknown
Link Fault
Unknown
Multiplexer State
Unknown
Parser Action
Unknown
Mode
Unknown
Supports
Unknown
OUI:
00:00:00
Enter, Previous Screen (0), (n)ext page, (H)elp, E(x)it >
To configure the 802.3ah parameters for the Port 2, type an n and press