Omnitron Systems Technology iConverter RS232 User Manual
Omnitron Systems Technology Communication
iConverter
®
RS232
Serial RS-232 to Fiber Media Converter
User Manual
Port 1 (P1)
Port 2 (P2)
OVERVIEW:
The Omnitron
iConverter
RS232 is a manageable serial
RS-232 to fiber converter that transmits serial signals
over fiber media. Fiber transmission can extend serial
signals up to 120km and is immune from electrical and
magnetic interference. The RS232 is available with a
single-mode, multimode or single-fiber transceiver. The
serial port is available with a DB-9 female connector or
terminal block connector.
The RS232 automatically detects the signal baud rate of
the connected serial device, ranging from 110 to 921,600
baud. The RS232 automatically adjusts to changes in
the connected device’s baud rate during operation, without
reconfiguration or interruption.
Connection to DTE or DCE devices is configured by an
easily accessible DIP-Switch on the front-panel. A built-
in remote Fiber Loop-Back DIP-Switch provides easy
validation of the entire fiber segment from either terminal
RS232 converter, without having to enable this function
on both converters.
The RS232 is designed to work in any
iConverter
chassis.
When installed in a multi-module chassis, the RS232 can
be remotely monitored and managed by software control.
The
iConverter
19-Module, 5-Module and 2-Module chassis
all support the software control feature. The 1-Module
chassis supports RS232 as a standalone serial to fiber
converter.
Note that software control for remote configuration
of the RS232 requires a multi-module chassis with
an
iConverter
Management Module, such as the
Network Management Module (NMM).
For more information on using and configuring
RS232 via software control, please refer to the
NetOutlook
™
Management Software user manual.
PORT STRUCTURE:
Front-Panel Ports:
The front-panel of the
iConverter
RS232 features one
fiber port (P1) and one RS-232 serial port (P2). Depending
on the model, the serial port is available either as a DB-9
female connector or as a terminal block for field wiring.
Please refer to Fig. 1a and Fig. 1b for connector pin-out
assignment.
Fig. 1a DB-9 Connector Pin-Out Assignment
Fig. 1b Terminal Block Pin-Out Assignment
DIP-SWITCH SETTINGS:
Fig. 2 Front-Panel DIP-Switches
SW1: Normal and Fiber Loop-Back “Norm / FLB”
DIP-Switch:
When the Normal and Fiber Loop-Back “Norm / FLB”
DIP-Switch is in the normal mode “Norm” position (factory
default), the Fiber Loop-Back is disabled. Setting this
DIP-Switch to the “FLB” position on the RS232 at either
end of the fiber segment will enable the Fiber Loop-Back
test. When Fiber Loop-back is enabled, the local RS232
with the DIP-Switch in “FLB” position is the master, and
the remote RS232 with the DIP-Switch in “Norm” position
is the slave. The “Tst” LED on the master will blink rapidly
(10 times per second) and the “Tst” LED on the slave will
blink slowly (once per second) if the fiber segment passes
the Loop-back test. If the fiber segment fails the Loop-
back test, the “Tst” LED on master unit will remain solid.
Note that the Fiber Loop-back test does not interfere
with serial conversion and signal transmission.
Note that only one RS232 on either end of the fiber
segment needs to be set to “FLB” position during
the Loop-back test.
SW2: Serial “DCE / DTE” DIP-Switch:
When the “DCE / DTE” DIP-Switch is in the “DCE” position
(factory default), the RS232 is configured to connect to
Data Communications Equipment such as a modem or
Page 1
Page 2
Page 3
Page 4
Page 5
iConverter
RS232 Models
Fiber Type /
Dual Fiber (DF) /
Wavelength (nm)
Distance
Fiber Connector Types
ST
SC
LC
MM/DF/1310
5km
8760-0
8762-0
-
SM/DF/1310
30km
8761-1
8763-1
8767-1
SM/DF/1310
60km
8761-2
8763-2
8767-2
SM/DF/1550
120km
-
8763-3
8767-3
When ordering module with terminal block serial port, append 'T'
before the dash '-' in the part number.
Examples: 8760T-0, 8763T-3, 8770T-1
iConverter RS232 Single-Fiber Models
Fiber Type /
or Single-Fiber (SF) /
Wavelength (nm)
Distance
Fiber Type
SC
SM/SF
Tx1310 / Rx1550
20km
8770-1
SM/SF
Tx 1550 / Rx 1310
20km
8771-1
SM/SF
Tx1310 / Rx1550
40km
8770-2
SM/SF
Tx 1550 / Rx 1310
40km
8771-2
For wide temperature (-40 to 60ºC), add a "W" to the end of the
model number. Consult factory for extended temperature
(-40 to +75ºC) models.
When using single-fiber (SF) media converter models, the Tx
wavelength on one end has to match the Rx wavelength on the other.
When ordering module with terminal block serial port, append 'T'
before the dash '-' in the part number. Examples: 8760T-0, 8763T-3
PIN No.
PIN Signal
Abbr.
DTE
DCE
1
Data Carrier Detect
DCD
IN
OUT
2
Received Data
RD
IN
OUT
3
Transmitted Data
TD
OUT
IN
4
Data Terminal Ready
DTR
OUT
IN
5
Signal Ground
SGND
-
-
6
Data Set Ready
DSR
IN
OUT
7
Request to Send
RTS
OUT
IN
8
Clear to Send
CTS
IN
OUT
9
Ring Indicator
RI
IN
OUT
printer. Setting this DIP-Switch to the “DTE” position
configures the RS232 to connect to Data Terminal
Equipment such as a computer or controller. Please refer
to the PORT STRUCTURE section of this manual for
more details.
MOUNTING AND CABLE ATTACHMENT:
iConverter
modules are hot-swappable and can be installed
into any chassis in the
iConverter
family.
1. After configuring the DIP-Switches, carefully slide
the
iConverter
module into the installation slot, aligning
the module with the installation guides. Ensure that
the module is firmly seated against the Backplane.
2. Secure the module by fastening the panel thumb screw
(attached to the module) to chassis front.
3. Attach the serial ports via a DB-9 serial cable (or an
open-end serial cable) to a serial RS-232 device.
4. Attach the fiber port via an appropriate multimode or
single-mode fiber cable to a 100BASE-FX Fast Ethernet
device. The
iConverter
transmit (Tx) must attach to
the receive side on the other device; the receive (Rx)
must attach to the transmit side.
5. When using single-fiber (SF) media converter models,
the Tx wavelength on one end has to match the Rx
wavelength on the other. Note that based on this
guideline the SF media converter models must be
used in pairs, such as the 8770-1 matched with the
8771-1.
RS232 LED INDICATORS:
RS232 SPECIFICATIONS:
Warning
The operating description in this Instruction Manual is for
use by qualified personnel only. To avoid electrical shock,
do not perform any servicing of this unit other than that
contained in the operating instructions, unless you are
qualified and certified to do so by Omnitron Systems
Technology, Inc.
Warranty
This product is warranted to the original purchaser against
defects in material and workmanship for a period of
TWO YEARS from the date of shipment. A LIFETIME
warranty may be obtained by the original purchaser by
REGISTERING this product with Omnitron within 90 days
from the date of shipment. TO REGISTER, COMPLETE
AND MAIL OR FAX THE ENCLOSED REGISTRATION
FORM TO THE INDICATED ADDRESS. Or you may
register your product on the Internet at www.omnitron-
systems.com. During the warranty period, Omnitron will,
at its option, repair or replace a product which is proven
to be defective.
For warranty service, the product must be sent to an
Omnitron designated facility, at Buyer ’s expense.
Omnitron will pay the shipping charge to return the product
to Buyer’s designated US address using Omnitron’s
standard shipping method.
Limitation of Warranty
The foregoing warranty shall not apply to defects resulting
from improper or inadequate use and/or maintenance of
the equipment by Buyer, Buyer-supplied equipment,
Buyer-supplied interfacing, unauthorized modifications
or tampering with equipment (including removal of
equipment cover by personnel not specifically authorized
and certified by Omnitron), or misuse, or operating outside
the environmental specification of the product (including
but not limited to voltage, ambient temperature, radiation,
unusual dust, etc.), or improper site preparation or
maintenance.
No other warranty is expressed or implied. Omnitron
specifically disclaims the implied warranties of
merchantability and fitness for any particular purpose.
Exclusive Remedies
The remedies provided herein are the Buyer’s sole and
exclusive remedies. Omnitron shall not be liable for any
direct, indirect, special, incidental, or consequential
damages, whether based on contract, tort, or any legal
theory.
TECHNICAL SUPPORT:
For help with this product, contact our Technical Support:
Phone:
(949) 250-6510
Fax:
(949) 250-6514
Address:
Omnitron Systems Technology, Inc.
140 Technology Dr.
Irvine, CA 92618 USA
E-mail:
URL:
www.omnitron-systems.com
Form: 040-08760-001D 12/12
Page 6
Page 7
Page 8
Page 9
Page 10
LED Function
"Legend"
Color
Off State
On / Blinking State
Power "Pwr"
Amber No Power
Module has power
Fiber Loop-
back Test "Tst"
Green
Normal
Mode
Solid: Master mode Tx
pattern sent, but no Rx
received
10 Hz (Blinking 10x per
second): Master mode, Tx
pattern sent, and Rx
pattern received
1 Hz (Blinking once per
second): Slave mode, Rx
pattern received
Fiber Link and
Activities "Act"
Green
No Fiber
Link
Solid: Fiber Link
Blinking:: Fiber Data
Transmission
"DTE" Mode
Green
DTE mode
not selected
DTE mode selected
"DCE" Mode
Green
DCE mode
not selected
DCE mode selected
Serial Activities
"Act"
Green
No serial
data
Serial data received
Model Type
RS232
Protocols
Asynchronous Serial RS-232
Copper
Connectors
DB-9 Female or
Terminal Block
Fiber
Connectors
ST, SC, LC
Controls
DTE/DCE, Fiber Loop-Back
LED Displays
Power, Test, Fiber Lnk/Act,
DTE, DCE, Serial Act
Dimensions
W:0.85" x D:4.5" x H:2.8"
Weight
8 oz.
Compliance
UL, CE, FCC Class A
Power
Requirement
0.5A @ 3.3VDC (typical)
Temperature
Standard: 0 to 50º C
Wide: -40 to 60º C
Storage: -40 to 80º C
Humidity
5 to 95% (non-condensing)
Altitude
-100m to 4000m
MTBF (hrs)
850,000