4 enabling/disabling soft-switch reload, Enabling/disabling soft-switch reload – Omnitron Systems Technology iConverter 2FXM User Manual User Manual
Page 19

3.4.4
Enabling/Disabling Soft-switch Reload
The Soft-switch Reload function controls the configurations of the 2FXM and other iConverter modules
managed by the 2FXM following a power up.
When the Soft-switch Reload is disabled, the configurations of the 2FXM and the other managed modules
(non-management modules) are determined by their hardware DIP-switch settings following a return of
power.
When the Soft-switch Reload is enabled, the configurations of the 2FXM and the other managed modules
are determined by the previous software settings stored in the FLASH memory of the 2FXM following a
return of power. Each of the hardware DIP-switch settings on the module are ignored until a change is
made to the DIP-switch, then the hardware settings will take effect.
To set the Soft-switch Reload function, select 8 at the IP and Control Preferences screen, press <ENTER>
and then follow the screen prompts to change the setting.
PI
SA
IP and Control Preferences Screen
iConverter, Serial Agent
1: Set IP
192.168.1.220
2: Set Subnet Mask
255.255.255.0
3: Set Gateway
192.168.1.1
4: Chassis Number
1
5: Chassis Name (also sysName)
2FXM
6: Enable/Disable TELNET
Enabled
7: Enable/Disable FTP
Disabled
8: Enable/Disable Soft Switch Reload
Disabled
9: TELNET Password
*****
10: FTP Password
11: Serial Password
Enter Choice, Management Options Screen(0), (H)elp, E(x)it >
To save the new values, select 0 and press
select 6 and press
Page 19