iConverter

X21 Standalone Module USER MANUAL

The Omnitron

iConverter

®

X21 is a serial to fiber media converter featuring several

configuration modes enabling connection to a wide variety of X.21 and RS-530
applications. Data rates of up to 8.192Mbps are supported.

T h e X 2 1 s u p p o r ts s ta n d a r d D C E
sourced timing and terminal timing
modes. The included adapter cable
accommodates different connector
gender types. The X21 features local
loopback on the serial and fiber ports
to facilitate testing and installations.

INSTALLATION PROCEDURE

1) Configure DIP-Switches

2) Install Standalone Module and Connect Cables

3) Verify Operation

1) CONFIGURE DIP-SWITCHES

FRONT PANEL DIP-SWITCH

SW1 - DCE/DTE

When this DIP-switch is in the “DCE” (default) position, the serial port is configured to
connect to a DCE device. When the DIP-switch is in the “DTE” position, the serial port
is configured to connect to a DTE device.

SW2 - SET CLOCK (RXC) POLARITY

When this DIP-switch is in the Receive Clock “RC” (default) position, the clock edge
used to sample the data on the serial port is defined by the TIA/EIA-334-C specification.
When the DIP-switch is in the Receive Clock Inverted “Inv” position, the data on the
serial port is sampled on the
inverted clock edge.

SW3 - DTE SET CLOCK
(TXC) POLARITY

When this DIP-switch is in the
Terminal Timing Clock “TTC”
(default) position, the clock edge
used to sample the data on the
serial port is defined by the TIA/
EIA-334-C specification. When
the DIP-switch is in the Terminal
Timing Clock Inverted “Inv”
position, the data on the serial
port is sampled on the inverted
clock edge.

The X.21 interface is a 2 row DB-15 connector.

Figure D: X.21 DB-15 Interface

A pinout cross reference table is provided showing the relationship between the serial
port and the X.21 interface. A DE-15 to DB-15 adapter cable is provided.

X.21

DB-15

PIN

Serial

Port

DE-15

PIN

Signal Name

Interchange

Circuit

(AKA)

Direction

Notes

DTE

DCE

2
9

11

1

Transmit +
Transmit -

T

(TXD)

IN

OUT

3

10

2
7

Control +
Control -

C

(RTS)

IN

OUT

4

11

8

12

Receive +
Receive -

R

(RXD)

OUT

IN

5

12

13

3

Indication +
Indication -

I

(CTS)

OUT

IN

6

13

4
9

Signal Element Timing +
Signal Element Timing -

S

(RXC)

OUT

IN

7

14

10
14

DTE Signal Element Timing +
DTE Signal Element Timing -

X

(TXC)

IN

OUT

1

6

Shield Ground

Sheild

N/A

Connect to Chassis Ground

8

15

Signal Ground

G

(GND)

N/A

Connect to Logic Ground

15

5

N/A

Spare Pin

3) VERIFY OPERATION

Once the module has been installed and configured per steps 1 and 2, verify the
module is operational by viewing the LED indicators.

The Power LED indicates the module is receiving power.

The Fiber Optic link LED indicates the fiber optic connection has been established.

Verify the serial port is configured for the correct mode of operation. Check the DCE/
DTE and TD/RD LEDs.

LED Function

"Legend"

Color

OFF State

ON State

Power
"Pwr"

Green

No power

Module has power

Fiber Optics
"P1"

Green

No Fiber Link

On: Fiber signal detected

Blinking: Activity

Fiber Optics
"Err"

Amber

No error detected

Error detected on fiber

(No clock or corrupted messages)

Serial Port
"DCE"

Green

Not configured for DCE-facing

Configured for connection to a DCE device

Serial Port
"DTE"

Green

Not configured for DTE-facing

Configured for connection to a DTE device

Timming Mode

"TD/RD"

Green

No activity / No clock detected

Blinking: Activity

Loopback
"Local LB""

Amber

Loopback/Test mode not

enabled

Blinking: Unit in loopback

Form 040-08840-001 B 5/08

Omnitron Systems Technology * 140 Technology Dr. #500 * Irvine, CA 92618

949.250.6510 tel * 949.250.6514 fax * www.omnitron-systems.com

SW1

SW4

Up

Down

Bank 1

SW1

SW4

Up

Down

Front Panel

Figure A: DIP-Switch Location