Omnitron Systems Technology iConverter X21 Standalone Module User Manual
Iconverter, X21 standalone module user manual, Installation procedure
iConverter
X21 Standalone Module USER MANUAL
The Omnitron
iConverter
®
X21 is a serial to fiber media converter featuring several
configuration modes enabling connection to a wide variety of X.21 and RS-530
applications. Data rates of up to 8.192Mbps are supported.
T h e X 2 1 s u p p o r ts s ta n d a r d D C E
sourced timing and terminal timing
modes. The included adapter cable
accommodates different connector
gender types. The X21 features local
loopback on the serial and fiber ports
to facilitate testing and installations.
INSTALLATION PROCEDURE
1) Configure DIP-Switches
2) Install Standalone Module and Connect Cables
3) Verify Operation
1) CONFIGURE DIP-SWITCHES
FRONT PANEL DIP-SWITCH
SW1 - DCE/DTE
When this DIP-switch is in the “DCE” (default) position, the serial port is configured to
connect to a DCE device. When the DIP-switch is in the “DTE” position, the serial port
is configured to connect to a DTE device.
SW2 - SET CLOCK (RXC) POLARITY
When this DIP-switch is in the Receive Clock “RC” (default) position, the clock edge
used to sample the data on the serial port is defined by the TIA/EIA-334-C specification.
When the DIP-switch is in the Receive Clock Inverted “Inv” position, the data on the
serial port is sampled on the
inverted clock edge.
SW3 - DTE SET CLOCK
(TXC) POLARITY
When this DIP-switch is in the
Terminal Timing Clock “TTC”
(default) position, the clock edge
used to sample the data on the
serial port is defined by the TIA/
EIA-334-C specification. When
the DIP-switch is in the Terminal
Timing Clock Inverted “Inv”
position, the data on the serial
port is sampled on the inverted
clock edge.
The X.21 interface is a 2 row DB-15 connector.
Figure D: X.21 DB-15 Interface
A pinout cross reference table is provided showing the relationship between the serial
port and the X.21 interface. A DE-15 to DB-15 adapter cable is provided.
X.21
DB-15
PIN
Serial
Port
DE-15
PIN
Signal Name
Interchange
Circuit
(AKA)
Direction
Notes
DTE
DCE
2
9
11
1
Transmit +
Transmit -
T
(TXD)
IN
OUT
3
10
2
7
Control +
Control -
C
(RTS)
IN
OUT
4
11
8
12
Receive +
Receive -
R
(RXD)
OUT
IN
5
12
13
3
Indication +
Indication -
I
(CTS)
OUT
IN
6
13
4
9
Signal Element Timing +
Signal Element Timing -
S
(RXC)
OUT
IN
7
14
10
14
DTE Signal Element Timing +
DTE Signal Element Timing -
X
(TXC)
IN
OUT
1
6
Shield Ground
Sheild
N/A
Connect to Chassis Ground
8
15
Signal Ground
G
(GND)
N/A
Connect to Logic Ground
15
5
N/A
Spare Pin
3) VERIFY OPERATION
Once the module has been installed and configured per steps 1 and 2, verify the
module is operational by viewing the LED indicators.
The Power LED indicates the module is receiving power.
The Fiber Optic link LED indicates the fiber optic connection has been established.
Verify the serial port is configured for the correct mode of operation. Check the DCE/
DTE and TD/RD LEDs.
LED Function
"Legend"
Color
OFF State
ON State
Power
"Pwr"
Green
No power
Module has power
Fiber Optics
"P1"
Green
No Fiber Link
On: Fiber signal detected
Blinking: Activity
Fiber Optics
"Err"
Amber
No error detected
Error detected on fiber
(No clock or corrupted messages)
Serial Port
"DCE"
Green
Not configured for DCE-facing
Configured for connection to a DCE device
Serial Port
"DTE"
Green
Not configured for DTE-facing
Configured for connection to a DTE device
Timming Mode
"TD/RD"
Green
No activity / No clock detected
Blinking: Activity
Loopback
"Local LB""
Amber
Loopback/Test mode not
enabled
Blinking: Unit in loopback
Form 040-08840-001 B 5/08
Omnitron Systems Technology * 140 Technology Dr. #500 * Irvine, CA 92618
949.250.6510 tel * 949.250.6514 fax * www.omnitron-systems.com
SW1
SW4
Up
Down
Bank 1
SW1
SW4
Up
Down
Front Panel
Figure A: DIP-Switch Location