the fault at the fiber port is propagated forward causing
the switch port to drop its link due to the propagated
fault [Fig 1(c)].
The Remote Fault Detection (RFD) mode transmits a
link signal only when a link signal is detected. When a
loss of link is detected, this mode will perform both a loop
back and propagate forward. For example, the fiber fault
is looped back in the opposite direction causing the port
on the other media converter to lose fiber link. It also
propagates the fault forward toward the UTP port causing
the switch port to lose link [Fig 1(d)].
Note: Connecting two converters set to RFD is an
illegal setting and will cause a “deadly embrace”
lockup.
Symmetrical Fault Detection is only supported on
modules with the revision of xx/08.
In Symmetrical Fault Detection (SFD), the UTP port
transmits a Link signal only when receiving a Link at
the fiber port. The fiber port transmits a Link signal only
when receiving a Link signal at both the fiber port and
the UTP port. As a result, fiber faults (no Link received
at the fiber) are looped back and can be reported to the
network core. In addition, connecting two back-to-back
converters which are both set to SFD facilitates dual-
loop-back, where fiber faults are reported to both ends of
the network link. A blinking fiber link LED on a converter
indicates a fault of the transmit fiber or UTP cables of
that converter [Fig. 1(e)].
Note: Converters in SFD mode must be deployed
in pairs.
FRONT PANEL DIP-SWITCH SETTINGS:
Link Prop = Link Propagate
R/Flt Det = Remote Fault Detect
Man = UTP Manual Negotiate
HDX = UTP Half-Duplex
Link Segment = Link Seg
Normal = Norm
UTP Auto Negotiate = AN
UTP Full-Duplex = FDX
SW1
SW4
Fig. 2 Front Panel DIP-Switches
SW1
SW2
Link Mode
LS
Normal Link Segment (LS)
LP
Normal Link Propagate (LP)
LS
RFD
Remote Fault Detection + LP
(RFD+LP)
LP
RFD
Illegal Setting
Fig. 3 Link Mode Selection Table
SW1
SW2
Link Mode
LS
Normal Link Segment (LS)
LP
Normal Link Propagate (LP)
LS
RFD
Remote Fault Detection + LP
(RFD+LP)
LP
RFD
Symmetrical Fault Detection (SFD)
Fig 4 Link Mode Selection Table for Revision xx/08
UTP Auto/Manual Negotiate “AN/Man” DIP-Switch:
When this DIP-Switch is in the UTP Auto-Negotiate
“AN” position (factory setting), the converter auto-
negotiates and matches the duplex mode of a mating
OVERVIEW:
The
iConverter
100Fx/Tx converters support the IEEE
802.3 Ethernet standard and converts 100BASE-FX fiber
to 100BASE-TX unshielded twisted pair (UTP). Models
are available for multimode (MM) and single-mode (SM)
dual fiber and single-mode single-fiber.
The 100Fx/Tx supports UTP Half-Duplex and Full-Duplex
auto-negotiation with manual override and features a
crossover UTP switch for easy attachment to hubs,
switches and workstations.
The 100Fx/Tx can be used in an unmanaged or managed
fashion. When unmanaged, it can be installed in a chassis
without an
iConverter
Network Management Module
(NMM) or
iConverter
10/100M2. To be managed, an
NMM module or 10/100M2 module must be installed in
the same chassis.
LINK MODES:
In order to accommodate different user needs, the 100Fx/
Tx supports three different linking modes.
The Link Segment (LS) mode transmits a link signal
independently of any received link at any port. Utilizing
this configuration, a loss of a receive link signal will only
affect the port detecting the loss of signal. All the other
ports will continue to generate a link signal. For example
a loss of link on the fiber port only affects the fiber port;
the other ports remain unaffected [Fig 1(b)].
The Link Propagate (LP) mode transmits a link signal only
when a link signal is detected. Utilizing this configuration,
a loss of a receive link signal will continue to propagate
through to the next port in the network. For example,
LED Lit
LED Blinking
LED Off
LED Status depends on connected device
Switch 1
Converter A
Converter B
Switch 2
(a)
LS
Fiber
UTP
UTP
Fiber
LS
Switch 1
Converter A
Converter B
Switch 2
LS
(b)
LS
(c)
Switch 1
Converter A
Converter B
Switch 2
LP
LP
(d)
Switch 1
Converter A
Converter B
Switch 2
SFD
SFD
(e)
Switch 1
Converter A
Converter B
Switch 2
LP
RFD+LP
Fig. 1 Link Modes
100Fx/Tx SPECIFICATIONS:
Page 7
Page 8
Page 9
Page 6
Page 10
Form: 040-08360-001J 02/14
Warning
The operating description in this Instruction Manual is
for use by qualified personnel only. To avoid electrical
shock, do not perform any servicing of this unit other than
that contained in the operating instructions, unless you
are qualified and certified to do so by Omnitron Systems
Technology, Inc.
Warranty
This product is warranted to the original purchaser
against defects in material and workmanship for a period
of TWO YEARS from the date of shipment. A LIFETIME
warranty may be obtained by the original purchaser by
REGISTERING this product with Omnitron within 90 days
from the date of shipment. TO REGISTER, COMPLETE
AND MAIL OR FAX THE ENCLOSED REGISTRATION
FORM TO THE INDICATED ADDRESS. Or you may
register your product on the Internet at www.omnitron-
systems.com. During the warranty period, Omnitron will,
at its option, repair or replace a product which is proven
to be defective.
For warranty service, the product must be sent to
an Omnitron designated facility, at Buyer’s expense.
Omnitron will pay the shipping charge to return the
product to Buyer’s designated US address using
Omnitron’s standard shipping method.
Limitation of Warranty
The foregoing warranty shall not apply to defects resulting
from improper or inadequate use and/or maintenance
of the equipment by Buyer, Buyer-supplied equipment,
Buyer-supplied interfacing, unauthorized modifications
or tampering with equipment (including removal of
equipment cover by personnel not specifically authorized
and certified by Omnitron), or misuse, or operating
outside the environmental specification of the product
(including but not limited to voltage, ambient temperature,
radiation, unusual dust, etc.), or improper site preparation
or maintenance.
No other warranty is expressed or implied. Omnitron
specifically disclaims the implied warranties of
merchantability and fitness for any particular purpose.
Exclusive Remedies
The remedies provided herein are the Buyer’s sole and
exclusive remedies. Omnitron shall not be liable for any
direct, indirect, special, incidental, or consequential
damages, whether based on contract, tort, or any legal
theory.
auto-negotiating device connected to its UTP port.
When in the UTP Manual Negotiate “Man” position,
the converter does not auto-negotiate and operates in
the duplex mode selected by the UTP Full/Half-Duplex
“FDX/HDX” DIP-Switch.
UTP Full/Half Duplex “FDX/HDX” DIP-Switch:
When the UTP Auto/Manual Negotiate “AN/Man”
DIP-Switch is in the Manual “Man” position, the UTP
Full/Half-Duplex “FDX/HDX” DIP-Switch determines the
duplex mode for the converter.
When the UTP Full/Half-Duplex DIP-Switch is in the UTP
Full-Duplex “FDX” position (factory setting), the converter
operates in Full-Duplex mode. When in the UTP Half-
Duplex “HDX” position, it operates in Half-Duplex mode.
Set the duplex mode to match the connecting device and
check for link status.
Note: Attaching an auto-negotiating UTP port to a
non-auto-negotiating (manual / forced / hard-coded)
UTP port may result in an unpredictable port setting
with excessive collisions and poor link performance.
When operating in Manual mode both mating ports
MUST be set manually to the same speed and duplex
mode.
RJ45 Crossover “= / X” Switch (Not Shown):
When connecting the UTP to a hub or switch, set this
front-plane switch to Straight-Through “=” (factory
setting). When connecting to a workstation, set it to
Crossover “X”.
Technical Support:
For help with this product, contact our Technical Support:
Phone:
(949) 250-6510
Fax:
(949) 250-6514
Address: Omnitron Systems Technology, Inc.
38 Tesla
Irvine, CA 92618 USA
Email:
URL:
www.omnitron-systems.com
LED INDICATORS:
LED Color
Description
Pwr:
Yellow On - Power on
F/O Lk:
Green On - Link; Blink - Activity
AN:
Green On - UTP Auto-Negotiation
enabled
FDx:
Green On - Full-Duplex mode
UTP/Lk:
Green On - UTP Link; Blink - Activity
MOUNTING AND CABLE ATTACHMENT:
The
iConverter
modules are hot-swappable and can be
installed into any
iConverter
chassis.
1. Using the chassis module guides for alignment, insert
the module into the selected slot and secure using the
front panel fastener screw.
Note: Ensure that the module is firmly seated
against the backplane.
2. Using a Category 5 cable, attach the UTP port to a
100BASE-TX Ethernet device.
3. Using a multimode or single-mode dual-fiber cable
as required per the converter type, attach the fiber
port to a 100BASE-FX mating Ethernet device. The
transmit (Tx) must attach to the receive side of the
mating device and the receive (Rx) must attach to the
transmit side.
4. Single-fiber (SF) converters must be used in matched
pairs. The transmit (Tx) and receive (Rx) wavelengths
of one converter must match the receive (Rx) and
transmit (Tx) wavelengths of the mating converter. For
example, an 8370-1 must be connected to an 8371-1.
Page 1
iConverter
®
100Fx/Tx User Manual
iConverter 100Fx/Tx Dual Fiber Modules
Fiber Type
Distance
Connector Types
ST
SC
LC
MM
5 km
8360-0
8362-0
8366-0
SM
30 km
8361-1
8363-1
8367-1
SM
60 km
8361-2
8363-2
8367-2
SM
120 km
-
8363-3
8367-3
iConverter 100Fx/Tx Single-Fiber Modules
Fiber /
Connector
Type
Distance
Tx: 1310nm,
Rx: 1550 nm
Tx: 1550nm,
Rx: 1310nm
SM/SC
20 km
8370-1
8371-1
SM/SC
40 km
8370-2
8371-2
For wide temperature (-40 to 60°C), add a “W” to the end of the model
number. Consult factory for extended temperature (-40 to +75°C)
models. When using single-fiber (SF) media converter models, the Tx
wavelength on one end has to match the Rx wavelength on the other.
Consult factory for additonal fiber configurations.
Model Type
100 Fx/Tx
Protocols
100BASE-FX, 100BASE-TX
Copper
Connectors
RJ-45
Fiber
Connectors
SC, ST, LC,
Single-Fiber SC
Controls
UTP X-over, LS/LP, RFD,
UTP FDX/HDX, UTP A/N
LED Displays
Power, FO link, UTP link,
Auto, FDX/HDX
Dimensions
W: 0.85” x D: 4.5” x H: 2.8”
Weight
8 oz.
Compliance
UL, CE, FCC Class A,
NEBS Level 3
Power
Requirement
0.7A @ 3.3VDC (typical)
Temperature
Standard: 0 to 50°C
Wide: -40 to 60°C
Storage: -40 to 80°C
Humidity
5 to 95% (non-condensing)
Altitude
-100m to 4000m
MTBF (hrs)
730,000